Parameter Specifications
| Parameter | 7.5K | 8K | 10K | 12K | 15K |
|---|---|---|---|---|---|
| PV Input | |||||
| Max. PV Input Power | 18 kW (9 / 9 kW) | 24 kW (12 / 12 kW) | |||
| Number of Independent MPPT Inputs | 2 (2:2) | ||||
| Max. PV Input Voltage | 480 V | ||||
| MPPT Voltage Range | 120–440 V | ||||
| Max. PV Input Current per MPPT | 26 / 26 A | 35 / 35 A | |||
| Battery | |||||
| Rated Battery Voltage | 48 / 51.2 V | ||||
| Max. Charging / Discharging Current | 180 A | 230 A | 250 A | ||
| Grid | |||||
| Rated AC Voltage | 120/240 V; 120/208 V | ||||
| Max. Continuous AC Passthrough Current | 100 A | ||||
| GEN | |||||
| Rated GEN Input Power | 10 kW | 15 kW | |||
| UPS | |||||
| Rated Output Power | 7.5 kW | 8 kW | 10 kW | 12 kW | 15 kW* |
| Surge Power, Duration | 2 × Rated Power for 5s | ||||
| Switching Time | <10 ms | ||||
| General | |||||
| Max. Parallel Units | 16 | ||||
| Dimensions (W × H × D) | 530 × 830 × 150 mm | ||||
| Ingress Protection Rating | IP20 | ||||
FAQ
Yes. The SNA-US 12–15K is designed for North American 120/240V split-phase systems and can supply applicable 120V and 240V household loads.
Yes. It can be used for whole-home backup applications. System design should consider the inverter’s rated backup output, 100A maximum bypass current, battery capability, and the home’s actual load demand.
The SNA-US 12–15K supports a maximum bypass current of 100A. For homes with a 200A electrical service, the system should be designed with this 100A bypass limit in mind.
Yes, as long as both the running power and startup surge are within the inverter and battery system capabilities. Motor-driven loads can require significantly higher power during startup.
Yes. A compatible generator can be integrated into the system to supply loads and charge the battery when solar or stored energy is insufficient.
Yes. It can operate with PV and battery storage without continuous utility-grid availability, making it suitable for off-grid and weak-grid applications.
Yes, depending on the existing system architecture. Retrofit and AC-coupled applications should be designed according to the existing PV inverter, system wiring and required backup functionality.
Compatible SNA-US units support parallel operation, allowing the system to increase power capacity and support future expansion. The installation must follow the applicable parallel configuration requirements.
Yes. With an internet connection and compatible communication device, users and authorized installers can monitor system operation through LuxCloud. Supported settings and firmware can also be managed remotely.
- Max. charging and discharging current: 250A
- 240/120V off-grid split-phase output
- 2 MPPTs with 4 strings, Max. 24kW PV input
- AFCI Protection Integrated