{"id":20139,"date":"2026-09-08T15:20:00","date_gmt":"2026-09-08T07:20:00","guid":{"rendered":"https:\/\/luxpowertek.com\/?page_id=20139"},"modified":"2026-09-08T15:20:00","modified_gmt":"2026-09-08T07:20:00","slug":"jakie-informacje-sa-potrzebne-do-malego-komercyjnego-projektu-solarno-bateryjnego-luxpowertek","status":"publish","type":"page","link":"https:\/\/luxpowertek.com\/pl\/knowledge\/what-information-is-needed-for-a-small-commercial-luxpowertek-solar-and-battery-project\/","title":{"rendered":"Jakich informacji potrzeba w przypadku ma\u0142ego, komercyjnego projektu LuxpowerTek wykorzystuj\u0105cego energi\u0119 s\u0142oneczn\u0105 i akumulatory?"},"content":{"rendered":"<h1>What information is needed for a small commercial LuxpowerTek solar and battery project?<\/h1>\n<p>A small commercial LuxpowerTek solar and battery project requires site-level electrical data (grid voltage, phase configuration, existing supply capacity), load profiling (daily energy consumption, peak demand, critical-load identification), PV array sizing details, battery capacity requirements, destination-market certifications, and monitoring preferences. Gathering this information early allows us to recommend the correct inverter family, confirm grid compliance, and size storage accurately.<\/p>\n<h2>Destination market and grid configuration<\/h2>\n<p>Small commercial projects sit at the boundary between residential-scale inverters and full C&#038;the buyer platforms. The first information we need is where the system will operate, because destination market determines which LuxpowerTek product family applies and which certifications must be met. Our EU-market inverters such as the GEN3-LB-EU 3-8K operate on 230 V single-phase grids, while our US-market three-phase models like the TriP2-LB-US 6-12K support split-phase 120\/240 V configurations. A project destined for a 380\/400 V three-phase commercial supply requires a different topology than a 208 V US light-commercial site.<\/p>\n<p>Confirm and document the following electrical parameters at the point of connection:<\/p>\n<ul>\n<li>Grid voltage and frequency (e.g., 230\/400 V 50 Hz, 120\/208 V 60 Hz)<\/li>\n<li>Single-phase or three-phase supply<\/li>\n<li>Main breaker rating and available headroom<\/li>\n<li>Whether the utility permits export, and any export-limit requirement<\/li>\n<li>Local interconnection standards and required certifications<\/li>\n<\/ul>\n<h2>Load and energy data<\/h2>\n<p>Accurate load profiling prevents both oversizing and undersizing of the battery bank, a common error discussed in our resource <a href=\"https:\/\/luxpowertek.com\/blog\/what-size-lifepo4-battery-for-solar-energy-storage-do-you-really-need\/\"><em>What Size LiFePO4 Battery for Solar Energy Storage Do You Really Need<\/em><\/a>. For a small commercial site we need:<\/p>\n<ul>\n<li>Average daily energy consumption (kWh per day, broken down by season if possible)<\/li>\n<li>Peak instantaneous demand (kW) and time-of-day pattern<\/li>\n<li>Critical loads that must remain powered during a grid outage, with their combined wattage<\/li>\n<li>Operating schedule (e.g., five-day retail, seven-day hospitality, shift patterns)<\/li>\n<li>Any demand-response or time-of-use programme participation, such as the programmes described on our <a href=\"https:\/\/luxpowertek.com\/demand-response-programme\/\">Demand Response Programme<\/a> page<\/li>\n<\/ul>\n<h2>PV array details<\/h2>\n<p>The solar input side must match the inverter&#8217;s MPPT voltage window and maximum PV power rating. Provide:<\/p>\n<ul>\n<li>Total proposed PV capacity (kWp)<\/li>\n<li>Module type, VOC, Isc, and string configuration<\/li>\n<li>Roof orientation, tilt, and any shading obstructions<\/li>\n<li>Whether this is a new installation or a DC retrofit of an existing PV farm \u2014 our Applications page documents a <a href=\"https:\/\/luxpowertek.com\/applications\/\">Japan LSP 100K PV farm DC retrofit<\/a> where nine units converted an existing 3.6 MWh solar farm into an energy storage system<\/li>\n<\/ul>\n<h2>Battery capacity and chemistry<\/h2>\n<p>LuxpowerTek <a href=\"https:\/\/luxpowertek.com\/hybrid-inverter\/\">hybrid inverters<\/a> support lithium-ion and lead-acid battery types across a 48 V nominal bus (with voltage windows varying by model). For commercial sizing we need to establish desired runtime, depth of discharge, and expansion plans.<\/p>\n<table>\n<thead>\n<tr>\n<th>Information item<\/th>\n<th>Why it matters<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Desired backup runtime (hours at critical load)<\/td>\n<td>Sets minimum usable battery capacity in kWh<\/td>\n<\/tr>\n<tr>\n<td>Battery chemistry preference (LiFePO4 recommended for cycle life)<\/td>\n<td>Affects BMS compatibility and charge profiles<\/td>\n<\/tr>\n<tr>\n<td>Ambient temperature range at battery location<\/td>\n<td>Determines derating and ventilation requirements<\/td>\n<\/tr>\n<tr>\n<td>Future expansion plans<\/td>\n<td>Informs whether to allow headroom for parallel battery strings<\/td>\n<\/tr>\n<tr>\n<td>Charge\/discharge rate required (C-rate)<\/td>\n<td>Must not exceed inverter max battery current<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Our <a href=\"https:\/\/luxpowertek.com\/battery-storage\/\">Battery Storage<\/a> page outlines both low-voltage and high-voltage configurations suited to different project scales.<\/p>\n<h2>Monitoring, commissioning, and documentation<\/h2>\n<p>Small commercial customers typically need remote monitoring for energy accounting and fault alerting. Confirm which <a href=\"https:\/\/luxpowertek.com\/monitoring\/\">monitoring platform<\/a> will be used, whether CT clamps or smart meters are already installed, and whether the site requires data export for compliance reporting. Additionally, gather:<\/p>\n<ul>\n<li>Site access constraints and commissioning schedule<\/li>\n<li>Whether AC coupling is needed to integrate an existing PV inverter (explained on our AC\/DC coupled Inverter FAQs page)<\/li>\n<li>Local permitting documents and utility application forms<\/li>\n<li>Installation contractor qualifications and any distributor support requirements<\/li>\n<\/ul>\n<h2>Practical preparation checklist<\/h2>\n<p>Use the following checklist to confirm readiness before requesting a formal project proposal from LuxpowerTek or our distribution partners:<\/p>\n<ol>\n<li>Grid voltage, phase count, and frequency confirmed<\/li>\n<li>Utility interconnection rules and export limits documented<\/li>\n<li>Twelve-month energy bills or interval meter data collected<\/li>\n<li>Critical-load schedule and wattage list prepared<\/li>\n<li>PV array layout and string design finalised<\/li>\n<li>Battery location, ventilation, and ambient temperature range assessed<\/li>\n<li>Desired backup runtime and future expansion scope defined<\/li>\n<li>Destination-market certification requirements identified<\/li>\n<li>Monitoring and reporting needs specified<\/li>\n<li>Commissioning timeline and site access plan agreed<\/li>\n<\/ol>\n<p>With these items documented, our engineering team can match the correct inverter model and battery architecture to the site, provide accurate system sizing, and ensure the project meets all local compliance requirements from day one.<\/p>\n<p><script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@context\":\"https:\/\/schema.org\",\"@type\":\"Article\",\"inLanguage\":\"en\",\"mainEntityOfPage\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/luxpowertek.com\/knowledge\/what-information-is-needed-for-a-small-commercial-luxpowertek-solar-and-battery-project\/\",\"datePublished\":\"2026-09-08T15:20:00+08:00\",\"dateModified\":\"2026-09-08T15:20:00+08:00\"},\"publisher\":{\"@type\":\"Organization\",\"name\":\"LuxpowerTek\",\"url\":\"https:\/\/luxpowertek.com\/\"},\"datePublished\":\"2026-09-08T15:20:00+08:00\",\"dateModified\":\"2026-09-08T15:20:00+08:00\",\"headline\":\"What information is needed for a small commercial LuxpowerTek solar and battery project?\",\"description\":\"A small commercial LuxpowerTek solar and battery project requires site-level electrical data (grid voltage, phase configuration, existing supply capacity), load profiling (daily energy consumption, peak demand, critical-load identification), PV array sizing details, battery capacity requirements, d\u2026\",\"articleBody\":\"What information is needed for a small commercial LuxpowerTek solar and battery project? A small commercial LuxpowerTek solar and battery project requires site-level electrical data (grid voltage, phase configuration, existing supply capacity), load profiling (daily energy consumption, peak demand, critical-load identification), PV array sizing details, battery capacity requirements, destination-market certifications, and monitoring preferences. Gathering this information early allows us to recommend the correct inverter family, confirm grid compliance, and size storage accurately. Destination market and grid configuration Small commercial projects sit at the boundary between residential-scale inverters and full C&the buyer platforms. The first information we need is where the system will operate, because destination market determines which LuxpowerTek product family applies and which certifications must be met. Our EU-market inverters such as the GEN3-LB-EU 3-8K operate on 230 V single-phase grids, while our US-market three-phase models like the TriP2-LB-US 6-12K support split-phase 120\/240 V configurations. A project destined for a 380\/400 V three-phase commercial supply requires a different topology than a 208 V US light-commercial site. Confirm and document the following electrical parameters at the point of connection: Grid voltage and frequency (e.g., 230\/400 V 50 Hz, 120\/208 V 60 Hz) Single-phase or three-phase supply Main breaker rating and available headroom Whether the utility permits export, and any export-limit requirement Local interconnection standards and required certifications Load and energy data Accurate load profiling prevents both oversizing and undersizing of the battery bank, a common error discussed in our resource What Size LiFePO4 Battery for Solar Energy Storage Do You Really Need . For a small commercial site we need: Average daily energy consumption (kWh per day, broken down by season if possible) Peak instantaneous demand (kW) and time-of-day pattern Critical loads that must remain powered during a grid outage, with their combined wattage Operating schedule (e.g., five-day retail, seven-day hospitality, shift patterns) Any demand-response or time-of-use programme participation, such as the programmes described on our Demand Response Programme page PV array details The solar input side must match the inverter's MPPT voltage window and maximum PV power rating. Provide: Total proposed PV capacity (kWp) Module type, VOC, Isc, and string configuration Roof orientation, tilt, and any shading obstructions Whether this is a new installation or a DC retrofit of an existing PV farm \u2014 our Applications page documents a Japan LSP 100K PV farm DC retrofit where nine units converted an existing 3.6 MWh solar farm into an energy storage system Battery capacity and chemistry LuxpowerTek hybrid inverters support lithium-ion and lead-acid battery types across a 48 V nominal bus (with voltage windows varying by model). For commercial sizing we need to establish desired runtime, depth of discharge, and expansion plans. Information item Why it matters Desired backup runtime (hours at critical load) Sets minimum usable battery capacity in kWh Battery chemistry preference (LiFePO4 recommended for cycle life) Affects BMS compatibility and charge profiles Ambient temperature range at battery location Determines derating and ventilation requirements Future expansion plans Informs whether to allow headroom for parallel battery strings Charge\/discharge rate required (C-rate) Must not exceed inverter max battery current Our Battery Storage page outlines both low-voltage and high-voltage configurations suited to different project scales. Monitoring, commissioning, and documentation Small commercial customers typically need remote monitoring for energy accounting and fault alerting. Confirm which monitoring platform will be used, whether CT clamps or smart meters are already installed, and whether the site requires data export for compliance reporting.\u2026\",\"author\":{\"@type\":\"Organization\",\"name\":\"LuxpowerTek\",\"url\":\"https:\/\/luxpowertek.com\/\"}},{\"@type\":\"HowTo\",\"name\":\"What information is needed for a small commercial LuxpowerTek solar and battery project?\",\"description\":\"A small commercial LuxpowerTek solar and battery project requires site-level electrical data (grid voltage, phase configuration, existing supply capacity), load profiling (daily energy consumption, peak demand, critical-load identification), PV array sizing details, battery capacity requirements, d\u2026\",\"mainEntityOfPage\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/luxpowertek.com\/knowledge\/what-information-is-needed-for-a-small-commercial-luxpowertek-solar-and-battery-project\/\",\"datePublished\":\"2026-09-08T15:20:00+08:00\",\"dateModified\":\"2026-09-08T15:20:00+08:00\"},\"datePublished\":\"2026-09-08T15:20:00+08:00\",\"dateModified\":\"2026-09-08T15:20:00+08:00\",\"step\":[{\"@type\":\"HowToStep\",\"name\":\"Grid voltage and frequency (e.g., 230\/400 V 50 Hz, 120\/208 V 60 Hz)\"},{\"@type\":\"HowToStep\",\"name\":\"Single-phase or three-phase supply\"},{\"@type\":\"HowToStep\",\"name\":\"Main breaker rating and available headroom\"},{\"@type\":\"HowToStep\",\"name\":\"Whether the utility permits export, and any export-limit requirement\"},{\"@type\":\"HowToStep\",\"name\":\"Local interconnection standards and required certifications\"},{\"@type\":\"HowToStep\",\"name\":\"Average daily energy consumption (kWh per day, broken down by season if possible)\"},{\"@type\":\"HowToStep\",\"name\":\"Peak instantaneous demand (kW) and time-of-day pattern\"},{\"@type\":\"HowToStep\",\"name\":\"Critical loads that must remain powered during a grid outage, with their combined wattage\"}]}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Jakie informacje s\u0105 potrzebne do ma\u0142ego, komercyjnego projektu instalacji fotowoltaicznej i akumulator\u00f3w LuxpowerTek? Ma\u0142y, komercyjny projekt instalacji fotowoltaicznej i akumulator\u00f3w LuxpowerTek wymaga danych elektrycznych na poziomie lokalizacji (napi\u0119cie sieci, konfiguracja faz, aktualna moc zasilania), profilowania obci\u0105\u017cenia (dzienne zu\u017cycie energii, szczytowe zapotrzebowanie, identyfikacja obci\u0105\u017cenia krytycznego), szczeg\u00f3\u0142\u00f3w dotycz\u0105cych wielko\u015bci instalacji fotowoltaicznej, wymaga\u0144 dotycz\u0105cych pojemno\u015bci akumulator\u00f3w, certyfikat\u00f3w dla rynk\u00f3w docelowych oraz preferencji dotycz\u0105cych monitorowania. Zebranie tych\u2026<\/p>","protected":false},"author":15,"featured_media":0,"parent":20135,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"rop_custom_images_group":[],"rop_custom_messages_group":[],"rop_publish_now":"initial","rop_publish_now_accounts":[],"rop_publish_now_history":[],"rop_publish_now_status":"pending","footnotes":""},"class_list":["post-20139","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>What information is needed for a small commercial LuxpowerTek solar and battery project? - LuxpowerTek<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/luxpowertek.com\/pl\/wiedza\/jakie-informacje-sa-potrzebne-do-malego-komercyjnego-projektu-solarno-bateryjnego-luxpowertek\/\" \/>\n<meta property=\"og:locale\" content=\"pl_PL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What information is needed for a small commercial LuxpowerTek solar and battery project? - LuxpowerTek\" \/>\n<meta property=\"og:description\" content=\"What information is needed for a small commercial LuxpowerTek solar and battery project? A small commercial LuxpowerTek solar and battery project requires site-level electrical data (grid voltage, phase configuration, existing supply capacity), load profiling (daily energy consumption, peak demand, critical-load identification), PV array sizing details, battery capacity requirements, destination-market certifications, and monitoring preferences. Gathering this...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/luxpowertek.com\/pl\/wiedza\/jakie-informacje-sa-potrzebne-do-malego-komercyjnego-projektu-solarno-bateryjnego-luxpowertek\/\" \/>\n<meta property=\"og:site_name\" content=\"LuxpowerTek\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/LUXPOWERTEK\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@luxpowertek\" \/>\n<meta name=\"twitter:label1\" content=\"Szacowany czas czytania\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minuty\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/knowledge\\\/what-information-is-needed-for-a-small-commercial-luxpowertek-solar-and-battery-project\\\/\",\"url\":\"https:\\\/\\\/luxpowertek.com\\\/knowledge\\\/what-information-is-needed-for-a-small-commercial-luxpowertek-solar-and-battery-project\\\/\",\"name\":\"What information is needed for a small commercial LuxpowerTek solar and battery project? - LuxpowerTek\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/#website\"},\"datePublished\":\"2026-09-08T07:20:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/knowledge\\\/what-information-is-needed-for-a-small-commercial-luxpowertek-solar-and-battery-project\\\/#breadcrumb\"},\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/luxpowertek.com\\\/knowledge\\\/what-information-is-needed-for-a-small-commercial-luxpowertek-solar-and-battery-project\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/knowledge\\\/what-information-is-needed-for-a-small-commercial-luxpowertek-solar-and-battery-project\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/luxpowertek.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Knowledge\",\"item\":\"https:\\\/\\\/luxpowertek.com\\\/knowledge\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"What information is needed for a small commercial LuxpowerTek solar and battery project?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/#website\",\"url\":\"https:\\\/\\\/luxpowertek.com\\\/\",\"name\":\"LuxpowerTek\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/luxpowertek.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pl-PL\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/#organization\",\"name\":\"LuxpowerTek\",\"url\":\"https:\\\/\\\/luxpowertek.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/luxpowertek.com\\\/wp-content\\\/uploads\\\/2024\\\/08\\\/Luxpower_logo_new.webp\",\"contentUrl\":\"https:\\\/\\\/luxpowertek.com\\\/wp-content\\\/uploads\\\/2024\\\/08\\\/Luxpower_logo_new.webp\",\"width\":1030,\"height\":186,\"caption\":\"LuxpowerTek\"},\"image\":{\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/LUXPOWERTEK\",\"https:\\\/\\\/x.com\\\/luxpowertek\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCS2wAmubDmcI44I_xKGWLQg\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/luxpowertek\\\/\",\"https:\\\/\\\/www.instagram.com\\\/luxpowertek?igsh=bWd0aXg3YWJzc3N0\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Jakie informacje s\u0105 potrzebne w przypadku ma\u0142ego komercyjnego projektu LuxpowerTek dotycz\u0105cego instalacji solarnych i akumulator\u00f3w? - LuxpowerTek","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/luxpowertek.com\/pl\/wiedza\/jakie-informacje-sa-potrzebne-do-malego-komercyjnego-projektu-solarno-bateryjnego-luxpowertek\/","og_locale":"pl_PL","og_type":"article","og_title":"What information is needed for a small commercial LuxpowerTek solar and battery project? - LuxpowerTek","og_description":"What information is needed for a small commercial LuxpowerTek solar and battery project? A small commercial LuxpowerTek solar and battery project requires site-level electrical data (grid voltage, phase configuration, existing supply capacity), load profiling (daily energy consumption, peak demand, critical-load identification), PV array sizing details, battery capacity requirements, destination-market certifications, and monitoring preferences. Gathering this...","og_url":"https:\/\/luxpowertek.com\/pl\/wiedza\/jakie-informacje-sa-potrzebne-do-malego-komercyjnego-projektu-solarno-bateryjnego-luxpowertek\/","og_site_name":"LuxpowerTek","article_publisher":"https:\/\/www.facebook.com\/LUXPOWERTEK","twitter_card":"summary_large_image","twitter_site":"@luxpowertek","twitter_misc":{"Szacowany czas czytania":"4 minuty"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/luxpowertek.com\/knowledge\/what-information-is-needed-for-a-small-commercial-luxpowertek-solar-and-battery-project\/","url":"https:\/\/luxpowertek.com\/knowledge\/what-information-is-needed-for-a-small-commercial-luxpowertek-solar-and-battery-project\/","name":"Jakie informacje s\u0105 potrzebne w przypadku ma\u0142ego komercyjnego projektu LuxpowerTek dotycz\u0105cego instalacji solarnych i akumulator\u00f3w? - LuxpowerTek","isPartOf":{"@id":"https:\/\/luxpowertek.com\/#website"},"datePublished":"2026-09-08T07:20:00+00:00","breadcrumb":{"@id":"https:\/\/luxpowertek.com\/knowledge\/what-information-is-needed-for-a-small-commercial-luxpowertek-solar-and-battery-project\/#breadcrumb"},"inLanguage":"pl-PL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/luxpowertek.com\/knowledge\/what-information-is-needed-for-a-small-commercial-luxpowertek-solar-and-battery-project\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/luxpowertek.com\/knowledge\/what-information-is-needed-for-a-small-commercial-luxpowertek-solar-and-battery-project\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/luxpowertek.com\/"},{"@type":"ListItem","position":2,"name":"Knowledge","item":"https:\/\/luxpowertek.com\/knowledge\/"},{"@type":"ListItem","position":3,"name":"What information is needed for a small commercial LuxpowerTek solar and battery project?"}]},{"@type":"WebSite","@id":"https:\/\/luxpowertek.com\/#website","url":"https:\/\/luxpowertek.com\/","name":"Powietrze","description":"","publisher":{"@id":"https:\/\/luxpowertek.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/luxpowertek.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pl-PL"},{"@type":"Organization","@id":"https:\/\/luxpowertek.com\/#organization","name":"Powietrze","url":"https:\/\/luxpowertek.com\/","logo":{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/luxpowertek.com\/#\/schema\/logo\/image\/","url":"https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/08\/Luxpower_logo_new.webp","contentUrl":"https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/08\/Luxpower_logo_new.webp","width":1030,"height":186,"caption":"LuxpowerTek"},"image":{"@id":"https:\/\/luxpowertek.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/LUXPOWERTEK","https:\/\/x.com\/luxpowertek","https:\/\/www.youtube.com\/channel\/UCS2wAmubDmcI44I_xKGWLQg","https:\/\/www.linkedin.com\/company\/luxpowertek\/","https:\/\/www.instagram.com\/luxpowertek?igsh=bWd0aXg3YWJzc3N0"]}]}},"_links":{"self":[{"href":"https:\/\/luxpowertek.com\/pl\/wp-json\/wp\/v2\/pages\/20139","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/luxpowertek.com\/pl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/luxpowertek.com\/pl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/luxpowertek.com\/pl\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/luxpowertek.com\/pl\/wp-json\/wp\/v2\/comments?post=20139"}],"version-history":[{"count":0,"href":"https:\/\/luxpowertek.com\/pl\/wp-json\/wp\/v2\/pages\/20139\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/luxpowertek.com\/pl\/wp-json\/wp\/v2\/pages\/20135"}],"wp:attachment":[{"href":"https:\/\/luxpowertek.com\/pl\/wp-json\/wp\/v2\/media?parent=20139"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}