{"id":6357,"date":"2023-05-31T19:23:44","date_gmt":"2023-05-31T11:23:44","guid":{"rendered":"https:\/\/luxpowertek.com\/?p=6357"},"modified":"2023-05-31T19:27:43","modified_gmt":"2023-05-31T11:27:43","slug":"mi-a-luxpower-ac-csatolasa","status":"publish","type":"post","link":"https:\/\/luxpowertek.com\/hu\/blog\/mi-a-luxpower-ac-csatolasa\/","title":{"rendered":"Mi a Luxpower AC csatol\u00e1sa?"},"content":{"rendered":"<p><span style=\"font-size: 130%\"><strong>Bevezet\u00e9s: <\/strong><\/span><\/p>\n<p>A mikroinverterek \u00e9s a h\u00e1l\u00f3zatra kapcsolt rendszerek sz\u00e9les k\u00f6r\u0171 eur\u00f3pai elterjed\u00e9s\u00e9vel a Luxpower kifejlesztett egy olyan modellt, amely alkalmas k\u00f6zvetlen h\u00e1l\u00f3zati csatlakoz\u00e1si rendszerekhez. Gyorsan \u00e1talak\u00edthatja a megl\u00e9v\u0151 mikroinvertereket vagy inverter rendszereket energiat\u00e1rol\u00f3 rendszerekk\u00e9. Ezenk\u00edv\u00fcl mag\u00e1ban foglalja a Luxpower intelligens kezel\u0151rendszer\u00e9t, amely automatikusan friss\u00edti az \u00e1ram\u00e1rakat, intelligensebb t\u00f6lt\u00e9si \u00e9s kis\u00fct\u00e9si m\u00f3dokat biztos\u00edt, integr\u00e1l egy UPS interf\u00e9szt, \u00e9s 40 A-es \u00e1tereszt\u0151k\u00e9pess\u00e9ggel rendelkezik, biztos\u00edtva a norm\u00e1l m\u0171k\u00f6d\u00e9st b\u00e1rmilyen \u00e1llapotban.<\/p>\n<p>I. Mi az AC csatol\u00e1s?<\/p>\n<p>II. A 3600ACS modell jellemz\u0151inek bemutat\u00e1sa.<\/p>\n<p>III. Aj\u00e1nlott minim\u00e1lis akkumul\u00e1torkapacit\u00e1s a csatlakoz\u00e1shoz.<\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"font-size: 120%\"><strong>I. Mi az AC csatol\u00e1s?<\/strong><\/span><\/p>\n<p>Egy v\u00e1ltakoz\u00f3 \u00e1ram\u00fa rendszerben a h\u00e1l\u00f3zatra kapcsolt fotovoltaikus inverter a 3600ACS kimenet\u00e9hez csatlakozik. A fotovoltaikus energi\u00e1t el\u0151sz\u00f6r a terhel\u00e9s t\u00e1pl\u00e1l\u00e1s\u00e1ra, majd az akkumul\u00e1tor t\u00f6lt\u00e9s\u00e9re haszn\u00e1lj\u00e1k. A felesleges fotovoltaikus energia visszat\u00e1pl\u00e1lhat\u00f3 a h\u00e1l\u00f3zatba.<\/p>\n<p>Amikor a 3600ACS inverter \u00fczemm\u00f3dban m\u0171k\u00f6dik, lekapcsol\u00f3dik a v\u00e1ltakoz\u00f3 \u00e1ram\u00fa bemenetr\u0151l, \u00e9s l\u00e9trehoz egy helyi h\u00e1l\u00f3zatot: egy mikroh\u00e1l\u00f3zatot. A PV inverter elfogadja ezt a mikroh\u00e1l\u00f3zatot, lehet\u0151v\u00e9 t\u00e9ve a folyamatos m\u0171k\u00f6d\u00e9st \u00e1ramkimarad\u00e1s eset\u00e9n is. A PV energia ak\u00e1r az akkumul\u00e1tor t\u00f6lt\u00e9s\u00e9re is felhaszn\u00e1lhat\u00f3. Amikor a rendelkez\u00e9sre \u00e1ll\u00f3 PV energia meghaladja a terhel\u00e9s \u00e1ltal fogyasztott energi\u00e1t, az energia automatikusan az ellenkez\u0151 ir\u00e1nyba \u00e1ramlik az inverteren kereszt\u00fcl, \u00e9s t\u00f6lti az akkumul\u00e1tort. Fontos megjegyezni, hogy az akkumul\u00e1tor megfelel\u0151 be\u00e1ll\u00edt\u00e1sait kell konfigur\u00e1lni a t\u00falt\u00f6lt\u00e9s \u00e9s az inverter\/t\u00f6lt\u0151 t\u00falterhel\u00e9s\u00e9nek elker\u00fcl\u00e9se \u00e9rdek\u00e9ben.<\/p>\n<p><span style=\"font-size: 120%\"><strong>II. A 3600 ACS modell jellemz\u0151i<\/strong><\/span><\/p>\n<p>Kiemel\u00e9s:<\/p>\n<ul>\n<li>Egyetlen 3600ACS egys\u00e9g egyf\u00e1zis\u00fa m\u0171k\u00f6d\u00e9sre van tervezve. H\u00e1romf\u00e1zis\u00fa terhel\u00e9sek eset\u00e9n h\u00e1rom 3600ACS egys\u00e9g kombin\u00e1lhat\u00f3.<\/li>\n<li>Az akkumul\u00e1toroldal 48 V-os l\u00edtium-ion vagy \u00f3lom-savas akkumul\u00e1torokat t\u00e1mogat, egys\u00e9genk\u00e9nt ak\u00e1r 100 Ah kapacit\u00e1ssal.<\/li>\n<li>K\u00fcl\u00f6nb\u00f6z\u0151 \u00f3lom-savas akkumul\u00e1torokkal \u00e9s a hagyom\u00e1nyos l\u00edtium-ion akkumul\u00e1torok sz\u00e9les v\u00e1laszt\u00e9k\u00e1val kompatibilis.<\/li>\n<li>Magas sk\u00e1l\u00e1zhat\u00f3s\u00e1got k\u00edn\u00e1l, lehet\u0151v\u00e9 t\u00e9ve az energiat\u00e1rol\u00f3 akkumul\u00e1torok \u00e9s a 3600ACS egyszer\u0171 hozz\u00e1ad\u00e1s\u00e1t a megl\u00e9v\u0151 fotovoltaikus rendszerekhez. Ez megk\u00f6nny\u00edti a j\u00f6v\u0151beni terhel\u00e9sb\u0151v\u00edt\u00e9st.<\/li>\n<li>Magas konverzi\u00f3s hat\u00e1sfok, ak\u00e1r 96% maxim\u00e1lis hat\u00e1sfokkal.<\/li>\n<li>Felhaszn\u00e1l\u00f3bar\u00e1t ember-g\u00e9p interf\u00e9sz, amely t\u00e1mogatja az RS485, Wi-Fi \u00e9s CAN kommunik\u00e1ci\u00f3t.<\/li>\n<li>S\u00falyos h\u00e1l\u00f3zati \u00e1ramkimarad\u00e1s eset\u00e9n az ACS 3600 d\u00edzelgener\u00e1torral is haszn\u00e1lhat\u00f3.<\/li>\n<li>A 3600ACS kompatibilis a piacon kaphat\u00f3 legt\u00f6bb PV inverter rendszerrel.<\/li>\n<li>A helyi el\u0151\u00edr\u00e1sokt\u00f3l f\u00fcgg\u0151en sz\u00fcks\u00e9g lehet egy sziget\u00fczem elleni v\u00e9delemre, ha t\u00fal sok energia \u00e1ramlik vissza a h\u00e1l\u00f3zatba.<\/li>\n<\/ul>\n<p><span style=\"font-size: 120%\"><strong>III. Aj\u00e1nlott minim\u00e1lis akkumul\u00e1torkapacit\u00e1s a csatlakoz\u00e1shoz<\/strong><\/span><\/p>\n<p>Az energiat\u00e1rol\u00f3 rendszerr\u00e9 alak\u00edt\u00e1shoz sz\u00fcks\u00e9ges minim\u00e1lis akkumul\u00e1torkapacit\u00e1s az akkumul\u00e1tor t\u00edpus\u00e1t\u00f3l f\u00fcgg, amely lehet \u00f3lom-savas vagy l\u00edtium.<\/p>\n<ul>\n<li>\u00d3lom-savas akkumul\u00e1torok eset\u00e9n aj\u00e1nlott minden kWp napelemhez egy 48 V\/100 Ah-s akkumul\u00e1tort haszn\u00e1lni.<\/li>\n<li>L\u00edtium-ion akkumul\u00e1torok eset\u00e9n aj\u00e1nlott minden 1,5 kWp napelem teljes\u00edtm\u00e9nyhez egy 48 V\/100 Ah-s akkumul\u00e1tort haszn\u00e1lni.<\/li>\n<\/ul>\n<p><span style=\"font-size: 120%\"><strong>Ut\u00f3irat:<\/strong><\/span><\/p>\n<p><span style=\"font-size: 120%\"><strong>D\u00edzelgener\u00e1tor csatlakoztat\u00e1s\u00e1nak \u00fczemm\u00f3dj\u00e1nak bemutat\u00e1sa<\/strong><\/span><\/p>\n<p>A napelemes rendszer, az energiat\u00e1rol\u00f3 akkumul\u00e1torok \u00e9s a d\u00edzelgener\u00e1tor egy mikroh\u00e1l\u00f3zatot alkot. A PV modulok h\u00e1romf\u00e1zis\u00fa v\u00e1ltakoz\u00f3 \u00e1ramot termelnek a terhel\u00e9sek sz\u00e1m\u00e1ra egy h\u00e1romf\u00e1zis\u00fa inverteren vagy h\u00e1rom vagy t\u00f6bb egyf\u00e1zis\u00fa inverteren kereszt\u00fcl. Amikor elegend\u0151 napf\u00e9ny van, \u00e9s a PV kimeneti teljes\u00edtm\u00e9nye meghaladja a terhel\u00e9s fogyaszt\u00e1s\u00e1t, a felesleges energi\u00e1t a 3600ACS az akkumul\u00e1torban t\u00e1rolja. Amikor a napf\u00e9ny nem elegend\u0151, \u00e9s a PV kimenete alacsonyabb, mint a terhel\u00e9s fogyaszt\u00e1sa, a 3600ACS az akkumul\u00e1torb\u00f3l k\u00e9pes energi\u00e1t mer\u00edteni a terhel\u00e9s ell\u00e1t\u00e1s\u00e1hoz. Amikor az akkumul\u00e1tor fesz\u00fclts\u00e9ge alacsony (pl. SOC = 20%, ez a param\u00e9ter a vez\u00e9rl\u0151rendszeren kereszt\u00fcl \u00e1ll\u00edthat\u00f3), a Sunny Island elind\u00edthatja a d\u00edzelgener\u00e1tort, szinkroniz\u00e1lhatja azt a d\u00edzelgener\u00e1tor \u00e1ltal termelt v\u00e1ltakoz\u00f3 \u00e1ram\u00fa h\u00e1l\u00f3zattal, \u00e9s energi\u00e1t tov\u00e1bb\u00edthat a terhel\u00e9s t\u00e1pl\u00e1l\u00e1s\u00e1hoz.<\/p>\n<p>A 3600ACS d\u00edzelvez\u00e9rl\u0151 funkci\u00f3ja megakad\u00e1lyozza az akkumul\u00e1tor t\u00falzott lemer\u00fcl\u00e9s\u00e9t, \u00e9s meghosszabb\u00edtja az akkumul\u00e1tor \u00e9lettartam\u00e1t, amikor a napf\u00e9ny nem elegend\u0151. D\u00edzelgener\u00e1torhoz csatlakoztatva a d\u00edzelvez\u00e9rl\u0151 biztos\u00edtja a f\u00fcggetlen h\u00e1l\u00f3zat fesz\u00fclts\u00e9g\u00e9t \u00e9s frekvenci\u00e1j\u00e1t. Amikor a fotovoltaikus teljes\u00edtm\u00e9ny nagyobb, mint a terhel\u00e9s, \u00e9s az akkumul\u00e1tor teljesen fel van t\u00f6ltve, a Sunny Island le tudja kapcsolni a d\u00edzelgener\u00e1tort, hogy elker\u00fclje a ford\u00edtott \u00e1ram visszafoly\u00e1s\u00e1t \u00e9s cs\u00f6kkentse az \u00fczemanyag-fogyaszt\u00e1st.<\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"font-size: 120%\"><strong>Tiszta, h\u00e1l\u00f3zaton k\u00edv\u00fcli \u00fczemm\u00f3d<\/strong><\/span><\/p>\n<p>D\u00edzelgener\u00e1tor n\u00e9lk\u00fcli, h\u00e1l\u00f3zaton k\u00edv\u00fcli rendszerekben a 3600ACS terhel\u00e9svez\u00e9rl\u00e9si funkci\u00f3val megakad\u00e1lyozhatja az akkumul\u00e1tor t\u00falzott lemer\u00fcl\u00e9s\u00e9t \u00e9s meghosszabb\u00edthatja az akkumul\u00e1tor \u00e9lettartam\u00e1t, amikor a napf\u00e9ny nem elegend\u0151.<\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"font-size: 130%\"><strong>\u00d6sszefoglal\u00e1s: <\/strong><\/span><\/p>\n<p>A 3600ACS egy AC-csatol\u00e1s\u00fa energiat\u00e1rol\u00f3 inverter, amelyet a megl\u00e9v\u0151 h\u00e1l\u00f3zatra kapcsolt fotovoltaikus rendszerekhez val\u00f3 csatlakoztat\u00e1sra \u00e9s energiat\u00e1rol\u00f3 inverterekk\u00e9 alak\u00edt\u00e1s\u00e1ra terveztek. Els\u0151sorban energiahi\u00e1nyos ter\u00fcleteken, p\u00e9ld\u00e1ul szigeteken, b\u00e1ny\u00e1kban, farmokon \u00e9s t\u00e1voli r\u00e9gi\u00f3kban alkalmazhat\u00f3, kiv\u00e1l\u00f3 megold\u00e1st k\u00edn\u00e1lva a h\u00e1l\u00f3zatra kapcsolt rendszerek korszer\u0171s\u00edt\u00e9s\u00e9re \u00e9s az elektromos h\u00e1l\u00f3zat instabilit\u00e1s\u00e1nak kezel\u00e9s\u00e9re.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Bevezet\u00e9s: A mikroinverterek \u00e9s a h\u00e1l\u00f3zatra kapcsolt rendszerek sz\u00e9les k\u00f6r\u0171 eur\u00f3pai elterjed\u00e9s\u00e9vel a Luxpower kifejlesztett egy olyan modellt, amely alkalmas k\u00f6zvetlen h\u00e1l\u00f3zati csatlakoz\u00e1si rendszerekhez. Gyorsan \u00e1talak\u00edthatja a megl\u00e9v\u0151 mikroinvertereket vagy inverter rendszereket energiat\u00e1rol\u00f3 rendszerekk\u00e9. Ezenk\u00edv\u00fcl mag\u00e1ban foglalja a Luxpower intelligens kezel\u0151rendszer\u00e9t, amely automatikusan friss\u00edti az \u00e1ram\u00e1rakat, intelligensebb t\u00f6lt\u00e9si \u00e9s kis\u00fct\u00e9si m\u00f3dokat biztos\u00edt,\u2026<\/p>","protected":false},"author":3,"featured_media":6358,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"rop_custom_images_group":[],"rop_custom_messages_group":[],"rop_publish_now":"initial","rop_publish_now_accounts":[],"rop_publish_now_history":[],"rop_publish_now_status":"pending","footnotes":""},"categories":[16],"tags":[],"class_list":["post-6357","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>What\u2019s the AC coupling from Luxpower? -<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/luxpowertek.com\/hu\/blog\/mi-a-luxpower-ac-csatolasa\/\" \/>\n<meta property=\"og:locale\" content=\"hu_HU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What\u2019s the AC coupling from Luxpower? -\" \/>\n<meta property=\"og:description\" content=\"Introduction: With the widespread use of microinverters and grid-tied systems in Europe, Luxpower has developed a model suitable for direct grid connection systems. It can quickly convert existing microinverters or inverter systems into energy storage systems. Additionally, it incorporates Luxpower&#8217;s intelligent management system, which automatically updates electricity prices, provides more intelligent charging and discharging modes,...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/luxpowertek.com\/hu\/blog\/mi-a-luxpower-ac-csatolasa\/\" \/>\n<meta property=\"article:published_time\" content=\"2023-05-31T11:23:44+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-05-31T11:27:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/luxpowertek.com\/wp-content\/uploads\/2023\/05\/Working-with-micro-gird-system-1-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"773\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"miao miao\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"miao miao\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 perc\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/blog\\\/whats-the-ac-coupling-from-luxpower\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/blog\\\/whats-the-ac-coupling-from-luxpower\\\/\"},\"author\":{\"name\":\"miao miao\",\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/#\\\/schema\\\/person\\\/691da96ccdd2a899702e96be4c0b892e\"},\"headline\":\"What\u2019s the AC coupling from Luxpower?\",\"datePublished\":\"2023-05-31T11:23:44+00:00\",\"dateModified\":\"2023-05-31T11:27:43+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/blog\\\/whats-the-ac-coupling-from-luxpower\\\/\"},\"wordCount\":756,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/blog\\\/whats-the-ac-coupling-from-luxpower\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/luxpowertek.com\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/Working-with-micro-gird-system-1-1.webp\",\"articleSection\":[\"About Products\"],\"inLanguage\":\"hu\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/luxpowertek.com\\\/blog\\\/whats-the-ac-coupling-from-luxpower\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/blog\\\/whats-the-ac-coupling-from-luxpower\\\/\",\"url\":\"https:\\\/\\\/luxpowertek.com\\\/blog\\\/whats-the-ac-coupling-from-luxpower\\\/\",\"name\":\"What\u2019s the AC coupling from Luxpower? -\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/blog\\\/whats-the-ac-coupling-from-luxpower\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/blog\\\/whats-the-ac-coupling-from-luxpower\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/luxpowertek.com\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/Working-with-micro-gird-system-1-1.webp\",\"datePublished\":\"2023-05-31T11:23:44+00:00\",\"dateModified\":\"2023-05-31T11:27:43+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/#\\\/schema\\\/person\\\/691da96ccdd2a899702e96be4c0b892e\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/blog\\\/whats-the-ac-coupling-from-luxpower\\\/#breadcrumb\"},\"inLanguage\":\"hu\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/luxpowertek.com\\\/blog\\\/whats-the-ac-coupling-from-luxpower\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"hu\",\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/blog\\\/whats-the-ac-coupling-from-luxpower\\\/#primaryimage\",\"url\":\"https:\\\/\\\/luxpowertek.com\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/Working-with-micro-gird-system-1-1.webp\",\"contentUrl\":\"https:\\\/\\\/luxpowertek.com\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/Working-with-micro-gird-system-1-1.webp\",\"width\":800,\"height\":773},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/blog\\\/whats-the-ac-coupling-from-luxpower\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/luxpowertek.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"About Products\",\"item\":\"https:\\\/\\\/luxpowertek.com\\\/zh\\\/blog\\\/\u7c7b\u522b\\\/\u65b0\u95fb\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"What\u2019s the AC coupling from Luxpower?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/#website\",\"url\":\"https:\\\/\\\/luxpowertek.com\\\/\",\"name\":\"\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/luxpowertek.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"hu\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/#\\\/schema\\\/person\\\/691da96ccdd2a899702e96be4c0b892e\",\"name\":\"miao miao\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"hu\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c9970439d619162f7823db50b8a803904cf5d449a40abe89abee48df8ed6fdad?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c9970439d619162f7823db50b8a803904cf5d449a40abe89abee48df8ed6fdad?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c9970439d619162f7823db50b8a803904cf5d449a40abe89abee48df8ed6fdad?s=96&d=mm&r=g\",\"caption\":\"miao miao\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Mi a Luxpower AC csatol\u00e1sa? -","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/luxpowertek.com\/hu\/blog\/mi-a-luxpower-ac-csatolasa\/","og_locale":"hu_HU","og_type":"article","og_title":"What\u2019s the AC coupling from Luxpower? -","og_description":"Introduction: With the widespread use of microinverters and grid-tied systems in Europe, Luxpower has developed a model suitable for direct grid connection systems. It can quickly convert existing microinverters or inverter systems into energy storage systems. Additionally, it incorporates Luxpower&#8217;s intelligent management system, which automatically updates electricity prices, provides more intelligent charging and discharging modes,...","og_url":"https:\/\/luxpowertek.com\/hu\/blog\/mi-a-luxpower-ac-csatolasa\/","article_published_time":"2023-05-31T11:23:44+00:00","article_modified_time":"2023-05-31T11:27:43+00:00","og_image":[{"width":800,"height":773,"url":"https:\/\/luxpowertek.com\/wp-content\/uploads\/2023\/05\/Working-with-micro-gird-system-1-1.webp","type":"image\/webp"}],"author":"miao miao","twitter_card":"summary_large_image","twitter_misc":{"Written by":"miao miao","Est. reading time":"4 perc"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/luxpowertek.com\/blog\/whats-the-ac-coupling-from-luxpower\/#article","isPartOf":{"@id":"https:\/\/luxpowertek.com\/blog\/whats-the-ac-coupling-from-luxpower\/"},"author":{"name":"miao miao","@id":"https:\/\/luxpowertek.com\/#\/schema\/person\/691da96ccdd2a899702e96be4c0b892e"},"headline":"What\u2019s the AC coupling from Luxpower?","datePublished":"2023-05-31T11:23:44+00:00","dateModified":"2023-05-31T11:27:43+00:00","mainEntityOfPage":{"@id":"https:\/\/luxpowertek.com\/blog\/whats-the-ac-coupling-from-luxpower\/"},"wordCount":756,"commentCount":0,"image":{"@id":"https:\/\/luxpowertek.com\/blog\/whats-the-ac-coupling-from-luxpower\/#primaryimage"},"thumbnailUrl":"https:\/\/luxpowertek.com\/wp-content\/uploads\/2023\/05\/Working-with-micro-gird-system-1-1.webp","articleSection":["About Products"],"inLanguage":"hu","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/luxpowertek.com\/blog\/whats-the-ac-coupling-from-luxpower\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/luxpowertek.com\/blog\/whats-the-ac-coupling-from-luxpower\/","url":"https:\/\/luxpowertek.com\/blog\/whats-the-ac-coupling-from-luxpower\/","name":"Mi a Luxpower AC csatol\u00e1sa? -","isPartOf":{"@id":"https:\/\/luxpowertek.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/luxpowertek.com\/blog\/whats-the-ac-coupling-from-luxpower\/#primaryimage"},"image":{"@id":"https:\/\/luxpowertek.com\/blog\/whats-the-ac-coupling-from-luxpower\/#primaryimage"},"thumbnailUrl":"https:\/\/luxpowertek.com\/wp-content\/uploads\/2023\/05\/Working-with-micro-gird-system-1-1.webp","datePublished":"2023-05-31T11:23:44+00:00","dateModified":"2023-05-31T11:27:43+00:00","author":{"@id":"https:\/\/luxpowertek.com\/#\/schema\/person\/691da96ccdd2a899702e96be4c0b892e"},"breadcrumb":{"@id":"https:\/\/luxpowertek.com\/blog\/whats-the-ac-coupling-from-luxpower\/#breadcrumb"},"inLanguage":"hu","potentialAction":[{"@type":"ReadAction","target":["https:\/\/luxpowertek.com\/blog\/whats-the-ac-coupling-from-luxpower\/"]}]},{"@type":"ImageObject","inLanguage":"hu","@id":"https:\/\/luxpowertek.com\/blog\/whats-the-ac-coupling-from-luxpower\/#primaryimage","url":"https:\/\/luxpowertek.com\/wp-content\/uploads\/2023\/05\/Working-with-micro-gird-system-1-1.webp","contentUrl":"https:\/\/luxpowertek.com\/wp-content\/uploads\/2023\/05\/Working-with-micro-gird-system-1-1.webp","width":800,"height":773},{"@type":"BreadcrumbList","@id":"https:\/\/luxpowertek.com\/blog\/whats-the-ac-coupling-from-luxpower\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/luxpowertek.com\/"},{"@type":"ListItem","position":2,"name":"About Products","item":"https:\/\/luxpowertek.com\/zh\/blog\/\u7c7b\u522b\/\u65b0\u95fb\/"},{"@type":"ListItem","position":3,"name":"What\u2019s the AC coupling from Luxpower?"}]},{"@type":"WebSite","@id":"https:\/\/luxpowertek.com\/#website","url":"https:\/\/luxpowertek.com\/","name":"","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/luxpowertek.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"hu"},{"@type":"Person","@id":"https:\/\/luxpowertek.com\/#\/schema\/person\/691da96ccdd2a899702e96be4c0b892e","name":"miao miao","image":{"@type":"ImageObject","inLanguage":"hu","@id":"https:\/\/secure.gravatar.com\/avatar\/c9970439d619162f7823db50b8a803904cf5d449a40abe89abee48df8ed6fdad?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c9970439d619162f7823db50b8a803904cf5d449a40abe89abee48df8ed6fdad?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c9970439d619162f7823db50b8a803904cf5d449a40abe89abee48df8ed6fdad?s=96&d=mm&r=g","caption":"miao miao"}}]}},"_links":{"self":[{"href":"https:\/\/luxpowertek.com\/hu\/wp-json\/wp\/v2\/posts\/6357","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/luxpowertek.com\/hu\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/luxpowertek.com\/hu\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/luxpowertek.com\/hu\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/luxpowertek.com\/hu\/wp-json\/wp\/v2\/comments?post=6357"}],"version-history":[{"count":0,"href":"https:\/\/luxpowertek.com\/hu\/wp-json\/wp\/v2\/posts\/6357\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/luxpowertek.com\/hu\/wp-json\/wp\/v2\/media\/6358"}],"wp:attachment":[{"href":"https:\/\/luxpowertek.com\/hu\/wp-json\/wp\/v2\/media?parent=6357"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/luxpowertek.com\/hu\/wp-json\/wp\/v2\/categories?post=6357"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/luxpowertek.com\/hu\/wp-json\/wp\/v2\/tags?post=6357"}],"curies":[{"name":"munkaf\u00fczet","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}