{"id":8254,"date":"2024-04-07T20:14:20","date_gmt":"2024-04-07T12:14:20","guid":{"rendered":"https:\/\/luxpowertek.com\/?page_id=8254"},"modified":"2025-11-07T16:29:36","modified_gmt":"2025-11-07T08:29:36","slug":"faq-new","status":"publish","type":"page","link":"https:\/\/luxpowertek.com\/ar\/faq-new\/","title":{"rendered":"FAQ new"},"content":{"rendered":"<div class=\"banner has-hover hide-for-small\" id=\"banner-1655178052\">\n          <div class=\"banner-inner fill\">\n        <div class=\"banner-bg fill\" >\n            <div class=\"bg fill bg-fill\"><\/div>\n                        <div class=\"overlay\"><\/div>            \n                    <\/div>\n\t\t\n        <div class=\"banner-layers container\">\n            <div class=\"fill banner-link\"><\/div>            \n   <div id=\"text-box-894877657\" class=\"text-box banner-layer x50 md-x50 lg-x50 y50 md-y50 lg-y50 res-text\">\n                                <div class=\"text-box-content text dark\">\n              \n              <div class=\"text-inner text-center\">\n                  \n\t<div id=\"text-1861031066\" class=\"text\">\n\t\t\n<h1 class=\"lead\"><span style=\"font-size: 100%;\"><strong>\u0627\u0644\u062a\u0639\u0644\u064a\u0645\u0627\u062a<\/strong><\/span><\/h1>\n<p class=\"lead\"><span style=\"font-size: 80%;\">Explore our FAQ for quick answers to your questions. We&#8217;re here to assist you every step of the way!<\/span><\/p>\n\t\t\n<style>\n#text-1861031066 {\n  font-size: 1.05rem;\n  line-height: 1.85;\n  text-align: center;\n}\n<\/style>\n\t<\/div>\n\t\n              <\/div>\n           <\/div>\n                            \n<style>\n#text-box-894877657 {\n  width: 76%;\n}\n#text-box-894877657 .text-box-content {\n  font-size: 100%;\n}\n<\/style>\n    <\/div>\n \n        <\/div>\n      <\/div>\n\n            \n<style>\n#banner-1655178052 {\n  padding-top: 500px;\n}\n#banner-1655178052 .bg.bg-loaded {\n  background-image: url(https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/04\/meet.webp);\n}\n#banner-1655178052 .overlay {\n  background-color: rgba(0, 0, 0, 0.459);\n}\n<\/style>\n  <\/div>\n\n\n\t<div id=\"gap-1907641226\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-1907641226 {\n  padding-top: 50px;\n}\n<\/style>\n\t<\/div>\n\t\n\t<section class=\"section hide-for-small\" id=\"section_750235907\">\n\t\t<div class=\"bg section-bg fill bg-fill  bg-loaded\" >\n\n\t\t\t\n\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row\"  id=\"row-560528735\">\n\n\t<div id=\"col-1151226304\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner text-left\"  >\n\t\t\t\n\t\t\t\n<p class=\"uppercase lead\"><span style=\"font-size: 100%;\"><strong>Solar Hybrid Inverter FAQs<\/strong><\/span><\/p>\n<p class=\"lead\"><span style=\"font-size: 80%;\">Here are some quick FAQs about our hybrid models. If the answers here don&#8217;t solve your query, please feel free to contact us.<\/span><\/p>\n<div class=\"slider-wrapper relative\" id=\"slider-1708082879\" >\n    <div class=\"slider slider-nav-circle slider-nav-large slider-nav-light slider-nav-outside slider-style-normal slider-show-nav\"\n        data-flickity-options='{            \"cellAlign\": \"center\",            \"imagesLoaded\": true,            \"lazyLoad\": 1,            \"freeScroll\": false,            \"wrapAround\": true,            \"autoPlay\": 6000,            \"pauseAutoPlayOnHover\" : true,            \"prevNextButtons\": true,            \"contain\" : true,            \"adaptiveHeight\" : true,            \"dragThreshold\" : 10,            \"percentPosition\": true,            \"pageDots\": true,            \"rightToLeft\": true,            \"draggable\": true,            \"selectedAttraction\": 0.1,            \"parallax\" : 0,            \"friction\": 0.6        }'\n        >\n        \n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1334202091\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1707\" src=\"https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/03\/GEN-3-6K-scaled.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/03\/GEN-3-6K-scaled.webp 2560w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/03\/GEN-3-6K-300x200.webp 300w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/03\/GEN-3-6K-1030x687.webp 1030w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/03\/GEN-3-6K-768x512.webp 768w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/03\/GEN-3-6K-1536x1024.webp 1536w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/03\/GEN-3-6K-2048x1365.webp 2048w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/03\/GEN-3-6K-510x340.webp 510w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1334202091 {\n  width: 63%;\n}\n<\/style>\n\t<\/div>\n\t\n     <\/div>\n\n     <div class=\"loading-spin dark large centered\"><\/div>\n\n\t<\/div>\n\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1460443853\" class=\"col medium-8 small-12 large-8\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<div class=\"accordion\">\n\t<div id=\"accordion-1293328240\" class=\"accordion-item\">\n\t\t<a id=\"accordion-1293328240-label\" class=\"accordion-title plain\" href=\"#accordion-item-does-lxp-us-12k-support-generator-remote-start-function?\" aria-expanded=\"false\" aria-controls=\"accordion-1293328240-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Does LXP-US 12K support Generator remote start function?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-1293328240-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-1293328240-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A: Yes, Luxpower 12kW series also facilitates the Generator auto-start function. To enable this feature, ensure your generator supports auto-start functionality. Simply connect a 2-wire cable directly to the dry contact port.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-1922366565\" class=\"accordion-item\">\n\t\t<a id=\"accordion-1922366565-label\" class=\"accordion-title plain\" href=\"#accordion-item-what&#039;s-the-function-of-dustproof-insulating-foam-for-mainboard\uff1f\" aria-expanded=\"false\" aria-controls=\"accordion-1922366565-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>What's the function of Dustproof Insulating foam for Mainboard\uff1f<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-1922366565-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-1922366565-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A: This component serves the purpose of preventing dust accumulation and isolating the mainboard. It plays a crucial role in safeguarding the mainboard against the harmful effects of dust, dirt, and other contaminants. Additionally, it provides insulation and shock absorption to ensure optimal functionality and longevity of the mainboard.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-91302004\" class=\"accordion-item\">\n\t\t<a id=\"accordion-91302004-label\" class=\"accordion-title plain\" href=\"#accordion-item-why-does-the-loss-of-sync-trigger-signal-happen-in-a-parallel-system?\" aria-expanded=\"false\" aria-controls=\"accordion-91302004-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Why does the loss of Sync trigger signal happen in a parallel system?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-91302004-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-91302004-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A: Before proceeding, please examine the parallel CAN cable and interface board. If necessary, consider replacing the interface board in this unit and conducting a thorough inspection. Should you require additional technical assistance, please don&#8217;t hesitate to reach out to our technical support team.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-1128767444\" class=\"accordion-item\">\n\t\t<a id=\"accordion-1128767444-label\" class=\"accordion-title plain\" href=\"#accordion-item-can-i-use-the-installer-account-to-block-an-end-user-from-changing-settings?\" aria-expanded=\"false\" aria-controls=\"accordion-1128767444-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Can I use the installer account to block an end user from changing settings?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-1128767444-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-1128767444-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A: Yes, you&#8217;ve adjusted the access to Read-Only. However, this setting doesn&#8217;t seem to apply when attempting to configure the inverter end using the LCD screen.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-8751069\" class=\"accordion-item\">\n\t\t<a id=\"accordion-8751069-label\" class=\"accordion-title plain\" href=\"#accordion-item-what-should-i-do-to-the-inverter-when-i-leave-home-for-a-long-time\uff1f\" aria-expanded=\"false\" aria-controls=\"accordion-8751069-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>What should I do to the inverter when I leave home for a long time\uff1f<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-8751069-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-8751069-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A: There&#8217;s no safety hazard when you leave home. And you can do the remote monitoring and setting through your app.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n<\/div>\n<div class=\"accordion\">\n<\/div>\n\t<div id=\"gap-1246047953\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-1246047953 {\n  padding-top: 30px;\n}\n<\/style>\n\t<\/div>\n\t\n<div class=\"row\"  id=\"row-474065964\">\n\n\t<div id=\"col-1748038118\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-209790263\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1758833387\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<a href=\"https:\/\/luxpowertek.com\/ar\/solar-hybrid-inverter-faqs\/\" class=\"button secondary is-outline\"  style=\"border-radius:23px;padding:0px 19px 0px 19px;\">\n    <span>\u0639\u0631\u0636 \u0627\u0644\u0645\u0632\u064a\u062f<\/span>\n  <i class=\"icon-angle-right\" aria-hidden=\"true\" ><\/i><\/a>\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1758833387 > .col-inner {\n  padding: 20px 45px 10px 36px;\n  margin: 2px 34px -1px 0px;\n}\n<\/style>\n\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_750235907 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n<\/style>\n\t<\/section>\n\t\n\t<section class=\"section hide-for-small\" id=\"section_2105609282\">\n\t\t<div class=\"bg section-bg fill bg-fill  bg-loaded\" >\n\n\t\t\t\n\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row\"  id=\"row-110736588\">\n\n\t<div id=\"col-1365294876\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<p class=\"lead\"><strong><span style=\"font-size: 100%;\">Off-grid Inverter FAQs<\/span><\/strong><\/p>\n<p class=\"lead\"><span style=\"font-size: 80%;\">Here are some quick FAQs about our off-grid models. If the answers here don&#8217;t solve your query, please feel free to contact us.<\/span><\/p>\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1373687963\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1707\" src=\"https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/04\/US-6K-scaled.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/04\/US-6K-scaled.webp 2560w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/04\/US-6K-300x200.webp 300w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/04\/US-6K-1030x687.webp 1030w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/04\/US-6K-768x512.webp 768w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/04\/US-6K-1536x1024.webp 1536w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/04\/US-6K-2048x1365.webp 2048w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/04\/US-6K-510x340.webp 510w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1373687963 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1365294876 > .col-inner {\n  padding: 0px 8px 28px 5px;\n  margin: 0px 0px 0px 0px;\n}\n<\/style>\n\t<\/div>\n\n\t\n\n\t<div id=\"col-299622758\" class=\"col medium-8 small-12 large-8\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<div class=\"accordion\">\n\t<div id=\"accordion-2910912958\" class=\"accordion-item\">\n\t\t<a id=\"accordion-2910912958-label\" class=\"accordion-title plain\" href=\"#accordion-item-is-it-normal-for-the-inverter-fan-to-run-almost-continuously-throughout-the-day?\" aria-expanded=\"false\" aria-controls=\"accordion-2910912958-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Is it normal for the inverter fan to run almost continuously throughout the day?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-2910912958-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-2910912958-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A:\u00a0In SNA inverters, the fan operates based on specific power thresholds. When charge or discharge power exceeds 300 watts, the left and middle fans activate. Additionally, the right fan engages when PV power exceeds 300 watts or grid import power exceeds 5000VA.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-2092025420\" class=\"accordion-item\">\n\t\t<a id=\"accordion-2092025420-label\" class=\"accordion-title plain\" href=\"#accordion-item-what-does-warning-code-00-on-the-sna5000-inverter-indicate?\" aria-expanded=\"false\" aria-controls=\"accordion-2092025420-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>What does warning code 00 on the SNA5000 inverter indicate?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-2092025420-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-2092025420-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A:\u00a0Warning code 00 signifies a &#8220;Battery communication fault,&#8221; indicating a failure in communication between the battery and the inverter. Additionally, Fault code 00 may suggest a communication issue between control CPUs, prompting a need for a firmware update or system restart. Status code 00 indicates &#8220;Standby&#8221; mode, indicating the inverter remains in standby due to unmet conditions to switch work modes.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-2835201232\" class=\"accordion-item\">\n\t\t<a id=\"accordion-2835201232-label\" class=\"accordion-title plain\" href=\"#accordion-item-why-does-my-sna-inverter-consistently-discharge-with-low-power-even-when-there-is-no-load-connected?\" aria-expanded=\"false\" aria-controls=\"accordion-2835201232-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Why does my SNA inverter consistently discharge with low power even when there is no load connected?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-2835201232-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-2835201232-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A: If the EPS (power backup) function is activated, the SNA inverter may display a load reading of less than 60 watts even when no load is connected to the EPS output port.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-1764401410\" class=\"accordion-item\">\n\t\t<a id=\"accordion-1764401410-label\" class=\"accordion-title plain\" href=\"#accordion-item-what-is-the-recommended-depth-of-discharge-for-the-battery,-and-how-can-it-be-adjusted?\" aria-expanded=\"false\" aria-controls=\"accordion-1764401410-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>What is the recommended depth of discharge for the battery, and how can it be adjusted?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-1764401410-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-1764401410-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A:\u00a0The recommended depth of discharge (DOD) depends on system design, including factors like battery capacity and load consumption. For systems with stable grid input aiming for an 80% DOD, adjust &#8220;On-grid cutoff SOC or On-grid EOD&#8221; to 20%. For systems with unstable or no grid input, set &#8220;Off-grid cutoff SOC or discharge cutoff SOC&#8221; to 20%, ensuring it&#8217;s lower than the &#8220;On-grid cutoff SOC&#8221; setting.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-4225249489\" class=\"accordion-item\">\n\t\t<a id=\"accordion-4225249489-label\" class=\"accordion-title plain\" href=\"#accordion-item-what-fault-conditions-prompt-the-inverter-to-shut-off-its-output?\" aria-expanded=\"false\" aria-controls=\"accordion-4225249489-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>What fault conditions prompt the inverter to shut off its output?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-4225249489-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-4225249489-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A: Various conditions such as overload, short circuit, PV overvoltage, overheat, or fan failure can trigger a fault in the inverter, causing it to shut off its output. Any abnormal conditions detected by the DSP will lead to a shutdown.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-2085312706\" class=\"accordion-item\">\n\t\t<a id=\"accordion-2085312706-label\" class=\"accordion-title plain\" href=\"#accordion-item-why-does-the-inverter-display-voltage-even-when-the-battery-breaker-is-off?\" aria-expanded=\"false\" aria-controls=\"accordion-2085312706-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Why does the inverter display voltage even when the battery breaker is off?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-2085312706-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-2085312706-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A:\u00a0If the battery operates in lithium mode with communication, voltage data originates from the battery&#8217;s BMs. However, if voltage readings persist after the battery breaker is turned off, it could indicate the battery was recently active or the inverter operated in charge mode.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n<\/div>\n<div class=\"accordion\">\n\t<div id=\"accordion-3349345502\" class=\"accordion-item\">\n\t\t<a id=\"accordion-3349345502-label\" class=\"accordion-title plain\" href=\"#accordion-item-i-installed-two-100ah-batteries,-but-the-monitoring-platform-shows-only-100ah.-why-is-that?\" aria-expanded=\"false\" aria-controls=\"accordion-3349345502-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>I installed two 100Ah batteries, but the monitoring platform shows only 100Ah. Why is that?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-3349345502-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-3349345502-label\" >\n\t\t\t\n<p style=\"font-weight: 400;\"><span style=\"font-size: 110%;\">A: The displayed current on the monitoring platform reflects data provided by the battery&#8217;s BMs. If the BMs accurately report a total current of 200Ah, the monitoring system will display 200Ah. Ensure to consult with the battery supplier for accurate information.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-2080539127\" class=\"accordion-item\">\n\t\t<a id=\"accordion-2080539127-label\" class=\"accordion-title plain\" href=\"#accordion-item-why-does-the-battery-state-of-charge-(soc)-experience-sudden-dramatic-increases?\" aria-expanded=\"false\" aria-controls=\"accordion-2080539127-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Why does the battery state of charge (SOC) experience sudden dramatic increases?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-2080539127-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-2080539127-label\" >\n\t\t\t\n<p style=\"font-weight: 400;\"><span style=\"font-size: 110%;\">A:<\/span> Sudden changes in SOC may result from battery SOC calibration issues. Check MaxCellVoltage and MinCellVoltage for imbalanced battery cell voltages.<\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-743843881\" class=\"accordion-item\">\n\t\t<a id=\"accordion-743843881-label\" class=\"accordion-title plain\" href=\"#accordion-item-why-does-the-grid-continue-charging-despite-ac-charge-being-disabled?\" aria-expanded=\"false\" aria-controls=\"accordion-743843881-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Why does the grid continue charging despite AC charge being disabled?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-743843881-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-743843881-label\" >\n\t\t\t\n<p style=\"font-weight: 400;\"><span style=\"font-size: 110%;\">A:<\/span> Check the battery status on the home page. If it shows specific codes like 0x10, 0x11, 0x12, 0x13, 0x20, 0x21, 0x22, or 0x23, it indicates the battery has requested forced charging.<\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-459339541\" class=\"accordion-item\">\n\t\t<a id=\"accordion-459339541-label\" class=\"accordion-title plain\" href=\"#accordion-item-the-battery-is-fully-charged,-yet-the-inverter-detects-a-battery-open-condition-(bat-volt-open).-why?\" aria-expanded=\"false\" aria-controls=\"accordion-459339541-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>The battery is fully charged, yet the inverter detects a battery open condition (Bat Volt Open). Why?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-459339541-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-459339541-label\" >\n\t\t\t\n<p style=\"font-weight: 400;\"><span style=\"font-size: 110%;\">A: This could occur due to an instantaneous power outage and recovery. After recovery, manually restart the inverter to clear the fault, or check if the charging power of the inverter exceeds 300W.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-3338955762\" class=\"accordion-item\">\n\t\t<a id=\"accordion-3338955762-label\" class=\"accordion-title plain\" href=\"#accordion-item-why-does-my-battery-show-full-charge-while-the-voltage-remains-unusually-low?\" aria-expanded=\"false\" aria-controls=\"accordion-3338955762-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Why does my battery show full charge while the voltage remains unusually low?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-3338955762-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-3338955762-label\" >\n\t\t\t\n<p style=\"font-weight: 400;\"><span style=\"font-size: 110%;\">A: If the battery operates in lithium mode, voltage data originates from the battery BMS and is unrelated to the inverter. In lead acid mode, SOC reading accuracy may vary, suggesting voltage control as an alternative approach.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n<\/div>\n\t<div id=\"gap-1331655750\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-1331655750 {\n  padding-top: 30px;\n}\n<\/style>\n\t<\/div>\n\t\n<div class=\"row\"  id=\"row-1569227947\">\n\n\t<div id=\"col-407017259\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-417804190\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1780816481\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<a href=\"https:\/\/luxpowertek.com\/ar\/offgridinverterfaq\/\" target=\"_blank\" class=\"button secondary is-outline\" rel=\"noopener\"  style=\"border-radius:99px;padding:0px 19px 0px 19px;\">\n    <span>\u0639\u0631\u0636 \u0627\u0644\u0645\u0632\u064a\u062f<\/span>\n  <i class=\"icon-angle-right\" aria-hidden=\"true\" ><\/i><\/a>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_2105609282 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n<\/style>\n\t<\/section>\n\t\n\t<section class=\"section hide-for-small\" id=\"section_140707257\">\n\t\t<div class=\"bg section-bg fill bg-fill  bg-loaded\" >\n\n\t\t\t\n\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row\"  id=\"row-1562772720\">\n\n\t<div id=\"col-1739751714\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<p class=\"lead\"><strong><span style=\"font-size: 100%;\">AC\/DC coupled FAQs<\/span><\/strong><\/p>\n<p class=\"lead\"><span style=\"font-size: 80%;\">Here are some quick FAQs about our AC\/DC models. If the answers here don&#8217;t solve your query, please feel free to contact us.<\/span><\/p>\n<div class=\"row\"  id=\"row-126825601\">\n\n\t<div id=\"col-432574668\" class=\"col medium-7 small-12 large-7\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1330841918\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1020\" height=\"776\" src=\"https:\/\/luxpowertek.com\/wp-content\/uploads\/2023\/10\/ACS-\u526f\u672c-1030x784.webp\" class=\"attachment-large size-large\" alt=\"Solar Inverters\" srcset=\"https:\/\/luxpowertek.com\/wp-content\/uploads\/2023\/10\/ACS-\u526f\u672c-1030x784.webp 1030w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2023\/10\/ACS-\u526f\u672c-300x228.webp 300w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2023\/10\/ACS-\u526f\u672c-768x584.webp 768w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2023\/10\/ACS-\u526f\u672c-1536x1169.webp 1536w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2023\/10\/ACS-\u526f\u672c-2048x1558.webp 2048w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2023\/10\/ACS-\u526f\u672c-800x609.webp 800w\" sizes=\"auto, (max-width: 1020px) 100vw, 1020px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1330841918 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-432574668 > .col-inner {\n  margin: 0px 0px 0px 70px;\n}\n<\/style>\n\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-2048341725\" class=\"col medium-8 small-12 large-8\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<div class=\"accordion\">\n\t<div id=\"accordion-1170684945\" class=\"accordion-item\">\n\t\t<a id=\"accordion-1170684945-label\" class=\"accordion-title plain\" href=\"#accordion-item-what-does-ac-coupling-mean\uff1f\" aria-expanded=\"false\" aria-controls=\"accordion-1170684945-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>What does AC COUPLING mean\uff1f<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-1170684945-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-1170684945-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A: AC coupling, or AC coupled, primarily refers to a storage system being charged from AC power. Typically used in retrofitting scenarios alongside existing PV systems, AC coupling allows for load compensation and battery charging when grid power is available. During grid outages, the storage system provides a voltage reference for the PV system to continue generating power without grid support.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-223718760\" class=\"accordion-item\">\n\t\t<a id=\"accordion-223718760-label\" class=\"accordion-title plain\" href=\"#accordion-item-is-ac-couple-in-on-grid-mode-and-off-grid-mode-available-with-12kw-inverter-?\" aria-expanded=\"false\" aria-controls=\"accordion-223718760-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Is AC couple in on-grid mode and off grid mode available with 12kw inverter ?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-223718760-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-223718760-label\" >\n\t\t\t\n<p>A: es, both on-grid and off-grid modes are available with a 12kW inverter. The existing PV inverter needs to be connected to the Gen port to enable AC coupling functionality.<\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-1496138105\" class=\"accordion-item\">\n\t\t<a id=\"accordion-1496138105-label\" class=\"accordion-title plain\" href=\"#accordion-item-can-acs3600-achieve-zero-export?\" aria-expanded=\"false\" aria-controls=\"accordion-1496138105-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Can ACS3600 achieve zero export?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-1496138105-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-1496138105-label\" >\n\t\t\t\n<p>A: The ACS3600 cannot achieve true zero export due to certain limitations:<\/p>\n<ol>\n<li>If the PV inverter lacks zero export functionality, setting zero export won&#8217;t work, resulting in excess energy feedback to the grid.<\/li>\n<li>If the PV inverter has zero export capability, it generates energy based on the load. When the current from the inverter is detected by a current transformer (CT), PV energy generation stops, preventing battery charging during this time.<\/li>\n<\/ol>\n\t\t<\/div>\n\t<\/div>\n\t\n<\/div>\n\t<div id=\"gap-1915384286\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-1915384286 {\n  padding-top: 30px;\n}\n<\/style>\n\t<\/div>\n\t\n<div class=\"row\"  id=\"row-18831407\">\n\n\t<div id=\"col-609285203\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-2008823888\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1541239315\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<a href=\"https:\/\/luxpowertek.com\/ar\/solarinverter-ac-dc-inverterfaq\/\" target=\"_blank\" class=\"button secondary is-outline\" rel=\"noopener\"  style=\"border-radius:99px;padding:0px 19px 0px 19px;\">\n    <span>\u0639\u0631\u0636 \u0627\u0644\u0645\u0632\u064a\u062f<\/span>\n  <i class=\"icon-angle-right\" aria-hidden=\"true\" ><\/i><\/a>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_140707257 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n<\/style>\n\t<\/section>\n\t\n\t<section class=\"section hide-for-small\" id=\"section_348416742\">\n\t\t<div class=\"bg section-bg fill bg-fill  bg-loaded\" >\n\n\t\t\t\n\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row\"  id=\"row-1216455986\">\n\n\t<div id=\"col-1637288850\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<p class=\"lead\"><strong><span style=\"font-size: 100%;\">Dongle FAQs<\/span><\/strong><\/p>\n<p class=\"lead\"><span style=\"font-size: 80%;\">Here are some quick FAQs about our dongle. If the answers here don&#8217;t solve your query, please feel free to contact us.<\/span><\/p>\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1374569429\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/luxpowertek.com\/wp-content\/uploads\/2021\/12\/Wifi-module.webp\" class=\"attachment-large size-large\" alt=\"\" srcset=\"https:\/\/luxpowertek.com\/wp-content\/uploads\/2021\/12\/Wifi-module.webp 800w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2021\/12\/Wifi-module-100x100.webp 100w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2021\/12\/Wifi-module-300x300.webp 300w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2021\/12\/Wifi-module-80x80.webp 80w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2021\/12\/Wifi-module-768x768.webp 768w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2021\/12\/Wifi-module-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1374569429 {\n  width: 68%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1797420779\" class=\"col medium-8 small-12 large-8\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<div class=\"accordion\">\n\t<div id=\"accordion-2953918175\" class=\"accordion-item\">\n\t\t<a id=\"accordion-2953918175-label\" class=\"accordion-title plain\" href=\"#accordion-item-how-do-i-connect-the-dongle-to-a-new-wifi-provider-if-i-change-my-router?\" aria-expanded=\"false\" aria-controls=\"accordion-2953918175-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>How do I connect the dongle to a new WiFi provider if I change my router?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-2953918175-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-2953918175-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A\uff1a Follow these steps to configure the new WiFi password via the app (ensure the new router supports the 2.4GHz frequency band):<\/span><\/p>\n<ul>\n<li>\n<p class=\"lead\"><span style=\"font-size: 80%;\">Insert the dongle into the inverter.<\/span><\/p>\n<\/li>\n<li>\n<p class=\"lead\"><span style=\"font-size: 80%;\">Connect your mobile phone or computer to the local hotspot sent by the WiFi dongle when the WiFi LED on the dongle is solid.<\/span><\/p>\n<\/li>\n<li>\n<p class=\"lead\"><span style=\"font-size: 80%;\">Open the Luxpowerview app and navigate to the &#8220;WiFi dongle connect&#8221; page.<\/span><\/p>\n<\/li>\n<li>\n<p class=\"lead\"><span style=\"font-size: 80%;\">Select your home WiFi network and input the password.<\/span><\/p>\n<\/li>\n<li>\n<p class=\"lead\"><span style=\"font-size: 80%;\">Click &#8220;Home WiFi connect&#8221; and wait for all three LED indicators to solidify.<\/span><\/p>\n<\/li>\n<\/ul>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-1557960051\" class=\"accordion-item\">\n\t\t<a id=\"accordion-1557960051-label\" class=\"accordion-title plain\" href=\"#accordion-item-why-isn&#039;t-my-4g-dongle-working?\" aria-expanded=\"false\" aria-controls=\"accordion-1557960051-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Why isn't my 4G dongle working?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-1557960051-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-1557960051-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A: Ensure that you have inserted the SIM card provided by LUX into the 4G dongle. If issues persist, please provide the 4G dongle serial number, inverter serial number, and SIM card serial number to Luxpower for inquiry regarding the validity period.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-479095121\" class=\"accordion-item\">\n\t\t<a id=\"accordion-479095121-label\" class=\"accordion-title plain\" href=\"#accordion-item-why-isn&#039;t-my-wifi-dongle-connecting-to-my-new-router?\" aria-expanded=\"false\" aria-controls=\"accordion-479095121-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Why isn't my WiFi dongle connecting to my new router?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-479095121-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-479095121-label\" >\n\t\t\t\n<p>A: Troubleshoot by checking the following:<\/p>\n<ul>\n<li>Verify if the router supports WiFi 5 protocol.<\/li>\n<li>Ensure the router is configured to WPA1\/WPA2\/WPA2\/3.<\/li>\n<li>Confirm if the router supports the 2.4GHz frequency band.<\/li>\n<li>Check if the router is configured to DHCP (or manually assign the IP address for the dongle).<\/li>\n<\/ul>\n\t\t<\/div>\n\t<\/div>\n\t\n<\/div>\n\t<div id=\"gap-238412530\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-238412530 {\n  padding-top: 30px;\n}\n<\/style>\n\t<\/div>\n\t\n<div class=\"row\"  id=\"row-800558635\">\n\n\t<div id=\"col-1048797085\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1831570052\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-487194135\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<a href=\"https:\/\/luxpowertek.com\/ar\/donglefaqs\/\" target=\"_blank\" class=\"button secondary is-outline\" rel=\"noopener\"  style=\"border-radius:99px;padding:0px 19px 0px 19px;\">\n    <span>\u0639\u0631\u0636 \u0627\u0644\u0645\u0632\u064a\u062f<\/span>\n  <i class=\"icon-angle-right\" aria-hidden=\"true\" ><\/i><\/a>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_348416742 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n<\/style>\n\t<\/section>\n\t\n\n  <div class=\"banner has-hover hide-for-small\" id=\"banner-2143576335\">\n          <div class=\"banner-inner fill\">\n        <div class=\"banner-bg fill\" >\n            <div class=\"bg fill bg-fill\"><\/div>\n                        <div class=\"overlay\"><\/div>            \n                    <\/div>\n\t\t\n        <div class=\"banner-layers container\">\n            <div class=\"fill banner-link\"><\/div>            \n   <div id=\"text-box-1126909031\" class=\"text-box banner-layer x50 md-x50 lg-x50 y50 md-y50 lg-y50 res-text\">\n                                <div class=\"text-box-content text dark\">\n              \n              <div class=\"text-inner text-center\">\n                  \n<p><span style=\"font-size: 200%;\"><strong>Still have questions?<\/strong><\/span><\/p>\n<p class=\"lead\"><strong><span style=\"font-size: 75%;\">Feel free to reach out to our support team for further assistance.<\/span><\/strong><\/p>\n<a href=\"https:\/\/luxpowertek.com\/ar\/contact_us\/\" target=\"_blank\" class=\"button white\" rel=\"noopener\"  style=\"border-radius:99px;\">\n    <span>Get Started<\/span>\n  <i class=\"icon-angle-right\" aria-hidden=\"true\" ><\/i><\/a>\n\n              <\/div>\n           <\/div>\n                            \n<style>\n#text-box-1126909031 {\n  width: 60%;\n}\n#text-box-1126909031 .text-box-content {\n  font-size: 100%;\n}\n<\/style>\n    <\/div>\n \n        <\/div>\n      <\/div>\n\n            \n<style>\n#banner-2143576335 {\n  padding-top: 500px;\n}\n#banner-2143576335 .bg.bg-loaded {\n  background-image: url(https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/04\/to-1.webp);\n}\n#banner-2143576335 .overlay {\n  background-color: rgba(0, 0, 0, 0.477);\n}\n<\/style>\n  <\/div>\n\n\n\t<section class=\"section show-for-small\" id=\"section_1904237974\">\n\t\t<div class=\"bg section-bg fill bg-fill  bg-loaded\" >\n\n\t\t\t\n\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n  <div class=\"banner has-hover show-for-small\" id=\"banner-890797530\">\n          <div class=\"banner-inner fill\">\n        <div class=\"banner-bg fill\" >\n            <div class=\"bg fill bg-fill\"><\/div>\n                        <div class=\"overlay\"><\/div>            \n                    <\/div>\n\t\t\n        <div class=\"banner-layers container\">\n            <div class=\"fill banner-link\"><\/div>            \n   <div id=\"text-box-124607992\" class=\"text-box banner-layer x50 md-x50 lg-x50 y90 md-y50 lg-y50 res-text\">\n                                <div class=\"text-box-content text dark\">\n              \n              <div class=\"text-inner text-center\">\n                  \n\t<div id=\"text-851093597\" class=\"text\">\n\t\t\n<h3 class=\"uppercase\"><span style=\"font-size: 130%;\"><strong>\u0627\u0644\u062a\u0639\u0644\u064a\u0645\u0627\u062a<\/strong><\/span><\/h3>\n<p><span style=\"font-size: 95%;\">Explore our FAQ for quick answers to your questions. We\u2019re here to assist you every step of the way!<\/span><\/p>\n\t\t\n<style>\n#text-851093597 {\n  font-size: 1rem;\n  line-height: 1.3;\n}\n<\/style>\n\t<\/div>\n\t\n              <\/div>\n           <\/div>\n                            \n<style>\n#text-box-124607992 {\n  width: 90%;\n}\n#text-box-124607992 .text-box-content {\n  font-size: 100%;\n}\n@media (min-width:550px) {\n  #text-box-124607992 {\n    width: 60%;\n  }\n}\n<\/style>\n    <\/div>\n \n        <\/div>\n      <\/div>\n\n            \n<style>\n#banner-890797530 {\n  padding-top: 210px;\n}\n#banner-890797530 .bg.bg-loaded {\n  background-image: url(https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/04\/meet.webp);\n}\n#banner-890797530 .overlay {\n  background-color: rgba(0, 0, 0, 0.31);\n}\n@media (min-width:550px) {\n  #banner-890797530 {\n    padding-top: 250px;\n  }\n}\n<\/style>\n  <\/div>\n\n\n\t<div id=\"gap-1043945535\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-1043945535 {\n  padding-top: 30px;\n}\n<\/style>\n\t<\/div>\n\t\n<div class=\"row\"  id=\"row-1994002073\">\n\n\t<div id=\"col-1991940736\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div id=\"text-2167777986\" class=\"text\">\n\t\t\n<h2>Solar Hybrid Inverter FAQs<\/h2>\n<p>Here are some quick FAQs about our hybrid models. If the answers here don\u2019t solve your query, please feel free to contact us.<\/p>\n\t\t\n<style>\n#text-2167777986 {\n  line-height: 1.75;\n}\n<\/style>\n\t<\/div>\n\t\n<a href=\"https:\/\/luxpowertek.com\/ar\/solar-hybrid-inverter-faqs\/\" class=\"button secondary is-outline\"  style=\"border-radius:23px;padding:0px 19px 0px 19px;\">\n    <span>\u0639\u0631\u0636 \u0627\u0644\u0645\u0632\u064a\u062f<\/span>\n  <i class=\"icon-angle-right\" aria-hidden=\"true\" ><\/i><\/a>\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_140679541\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" style=\"margin:0px -18px 0px 0px;\">\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1707\" src=\"https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/03\/GEN-3-6K-scaled.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/03\/GEN-3-6K-scaled.webp 2560w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/03\/GEN-3-6K-300x200.webp 300w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/03\/GEN-3-6K-1030x687.webp 1030w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/03\/GEN-3-6K-768x512.webp 768w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/03\/GEN-3-6K-1536x1024.webp 1536w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/03\/GEN-3-6K-2048x1365.webp 2048w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/03\/GEN-3-6K-510x340.webp 510w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_140679541 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t<div id=\"gap-89072293\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-89072293 {\n  padding-top: 20px;\n}\n@media (min-width:550px) {\n  #gap-89072293 {\n    padding-top: 30px;\n  }\n}\n<\/style>\n\t<\/div>\n\t\n<div class=\"accordion\">\n\t<div id=\"accordion-2461698669\" class=\"accordion-item\">\n\t\t<a id=\"accordion-2461698669-label\" class=\"accordion-title plain\" href=\"#accordion-item-does-lxp-us-12k-support-cenerator-remote-start-function?\" aria-expanded=\"false\" aria-controls=\"accordion-2461698669-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Does LXP-Us 12K support cenerator remote start function?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-2461698669-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-2461698669-label\" >\n\t\t\t\n\t<div id=\"text-982519805\" class=\"text\">\n\t\t\n<p>A:\u00a0 Yes, Luxpower 12kW series also facilitates the Generator auto-start function. To enable this feature, ensure your generator supports auto-start functionality. Simply connect a 2-wire cable directly to the dry contact port.<\/p>\n\t\t\n<style>\n#text-982519805 {\n  font-size: 0.96rem;\n  line-height: 1.75;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-812418624\" class=\"accordion-item\">\n\t\t<a id=\"accordion-812418624-label\" class=\"accordion-title plain\" href=\"#accordion-item-what&#039;s-the-function-of-dustproof-insulating-foam-for-mainboard?\" aria-expanded=\"false\" aria-controls=\"accordion-812418624-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>What's the function of Dustproof insulating foam for Mainboard?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-812418624-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-812418624-label\" >\n\t\t\t\n\t<div id=\"text-40161930\" class=\"text\">\n\t\t\n<p>A:\u00a0 \u00a0This component serves the purpose of preventing dust accumulation and isolating the mainboard. It plays a crucial role in safeguarding the mainboard against the harmful effects of dust, dirt, and other contaminants. Additionally, it provides insulation and shock absorption to ensure optimal functionality and longevity of the mainboard.<\/p>\n\t\t\n<style>\n#text-40161930 {\n  font-size: 0.96rem;\n  line-height: 1.75;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-1929295637\" class=\"accordion-item\">\n\t\t<a id=\"accordion-1929295637-label\" class=\"accordion-title plain\" href=\"#accordion-item-why-does-the-loss-of-sync-trigger-signal-happen-in-a-parallel-system?\" aria-expanded=\"false\" aria-controls=\"accordion-1929295637-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Why does the loss of Sync trigger signal happen in a parallel system?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-1929295637-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-1929295637-label\" >\n\t\t\t\n\t<div id=\"text-2531888074\" class=\"text\">\n\t\t\n<p>A:\u00a0 \u00a0Before proceeding, please examine the parallel CAN cable and interface board. If necessary, consider replacing the interface board in this unit and conducting a thorough inspection. Should you require additional technical assistance, please don\u2019t hesitate to reach out to our technical support team.<\/p>\n\t\t\n<style>\n#text-2531888074 {\n  font-size: 0.96rem;\n  line-height: 1.75;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-1932479094\" class=\"accordion-item\">\n\t\t<a id=\"accordion-1932479094-label\" class=\"accordion-title plain\" href=\"#accordion-item-can-luse-the-installer-account-to-block-an-end-user-from-changing-settings?\" aria-expanded=\"false\" aria-controls=\"accordion-1932479094-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Can luse the installer account to block an end user from changing settings?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-1932479094-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-1932479094-label\" >\n\t\t\t\n\t<div id=\"text-202487779\" class=\"text\">\n\t\t\n<p>A:\u00a0 \u00a0Yes, you\u2019ve adjusted the access to Read-Only. However, this setting doesn\u2019t seem to apply when attempting to configure the inverter end using the LCD screen.<\/p>\n\t\t\n<style>\n#text-202487779 {\n  font-size: 0.96rem;\n  line-height: 1.75;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-2662677971\" class=\"accordion-item\">\n\t\t<a id=\"accordion-2662677971-label\" class=\"accordion-title plain\" href=\"#accordion-item-what-should-l-do-to-the-inverter-when-l-leave-home-for-a-long-time?\" aria-expanded=\"false\" aria-controls=\"accordion-2662677971-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>What should l do to the inverter when l leave home for a long time?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-2662677971-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-2662677971-label\" >\n\t\t\t\n\t<div id=\"text-1596778837\" class=\"text\">\n\t\t\n<p>A:\u00a0 \u00a0There\u2019s no safety hazard when you leave home. And you can do the remote monitoring and setting through your app.<\/p>\n\t\t\n<style>\n#text-1596778837 {\n  font-size: 0.96rem;\n  line-height: 1.75;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t<\/div>\n\t\n<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-328068179\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div id=\"gap-434686938\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-434686938 {\n  padding-top: 10px;\n}\n@media (min-width:550px) {\n  #gap-434686938 {\n    padding-top: 30px;\n  }\n}\n<\/style>\n\t<\/div>\n\t\n<div class=\"text-center\"><div class=\"is-divider divider clearfix\" style=\"max-width:350px;background-color:#488064;\"><\/div><\/div>\n\t<div id=\"gap-847679619\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-847679619 {\n  padding-top: 30px;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-269418635\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div id=\"text-4253149874\" class=\"text\">\n\t\t\n<h2>Off-grid Inverter FAQs<\/h2>\n<p>Here are some quick FAQs about our off-grid models. If the answers here don\u2019t solve your query, please feel free to contact us.<\/p>\n\t\t\n<style>\n#text-4253149874 {\n  line-height: 1.75;\n}\n<\/style>\n\t<\/div>\n\t\n<a href=\"https:\/\/luxpowertek.com\/ar\/offgridinverterfaq\/\" class=\"button secondary is-outline\"  style=\"border-radius:23px;padding:0px 19px 0px 19px;\">\n    <span>\u0639\u0631\u0636 \u0627\u0644\u0645\u0632\u064a\u062f<\/span>\n  <i class=\"icon-angle-right\" aria-hidden=\"true\" ><\/i><\/a>\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_820587271\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" style=\"margin:0px 0px 0px 0px;\">\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1707\" src=\"https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/04\/US-6K-scaled.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/04\/US-6K-scaled.webp 2560w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/04\/US-6K-300x200.webp 300w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/04\/US-6K-1030x687.webp 1030w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/04\/US-6K-768x512.webp 768w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/04\/US-6K-1536x1024.webp 1536w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/04\/US-6K-2048x1365.webp 2048w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/04\/US-6K-510x340.webp 510w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_820587271 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t<div id=\"gap-803498005\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-803498005 {\n  padding-top: 20px;\n}\n@media (min-width:550px) {\n  #gap-803498005 {\n    padding-top: 30px;\n  }\n}\n<\/style>\n\t<\/div>\n\t\n<div class=\"accordion\">\n\t<div id=\"accordion-647717978\" class=\"accordion-item\">\n\t\t<a id=\"accordion-647717978-label\" class=\"accordion-title plain\" href=\"#accordion-item-is-it-normal-for-the-inverter-fan-to-run-almost-continuously-throughout-the-day?\" aria-expanded=\"false\" aria-controls=\"accordion-647717978-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Is it normal for the inverter fan to run almost continuously throughout the day?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-647717978-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-647717978-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A:\u00a0In SNA inverters, the fan operates based on specific power thresholds. When charge or discharge power exceeds 300 watts, the left and middle fans activate. Additionally, the right fan engages when PV power exceeds 300 watts or grid import power exceeds 5000VA.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-1314383178\" class=\"accordion-item\">\n\t\t<a id=\"accordion-1314383178-label\" class=\"accordion-title plain\" href=\"#accordion-item-what-does-warning-code-00-on-the-sna5000-inverter-indicate?\" aria-expanded=\"false\" aria-controls=\"accordion-1314383178-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>What does warning code 00 on the SNA5000 inverter indicate?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-1314383178-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-1314383178-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A:\u00a0Warning code 00 signifies a &#8220;Battery communication fault,&#8221; indicating a failure in communication between the battery and the inverter. Additionally, Fault code 00 may suggest a communication issue between control CPUs, prompting a need for a firmware update or system restart. Status code 00 indicates &#8220;Standby&#8221; mode, indicating the inverter remains in standby due to unmet conditions to switch work modes.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-1566288609\" class=\"accordion-item\">\n\t\t<a id=\"accordion-1566288609-label\" class=\"accordion-title plain\" href=\"#accordion-item-why-does-my-sna-inverter-consistently-discharge-with-low-power-even-when-there-is-no-load-connected?\" aria-expanded=\"false\" aria-controls=\"accordion-1566288609-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Why does my SNA inverter consistently discharge with low power even when there is no load connected?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-1566288609-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-1566288609-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A: If the EPS (power backup) function is activated, the SNA inverter may display a load reading of less than 60 watts even when no load is connected to the EPS output port.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-3206947466\" class=\"accordion-item\">\n\t\t<a id=\"accordion-3206947466-label\" class=\"accordion-title plain\" href=\"#accordion-item-what-is-the-recommended-depth-of-discharge-for-the-battery,-and-how-can-it-be-adjusted?\" aria-expanded=\"false\" aria-controls=\"accordion-3206947466-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>What is the recommended depth of discharge for the battery, and how can it be adjusted?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-3206947466-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-3206947466-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A:\u00a0The recommended depth of discharge (DOD) depends on system design, including factors like battery capacity and load consumption. For systems with stable grid input aiming for an 80% DOD, adjust &#8220;On-grid cutoff SOC or On-grid EOD&#8221; to 20%. For systems with unstable or no grid input, set &#8220;Off-grid cutoff SOC or discharge cutoff SOC&#8221; to 20%, ensuring it&#8217;s lower than the &#8220;On-grid cutoff SOC&#8221; setting.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-1764585984\" class=\"accordion-item\">\n\t\t<a id=\"accordion-1764585984-label\" class=\"accordion-title plain\" href=\"#accordion-item-what-fault-conditions-prompt-the-inverter-to-shut-off-its-output?\" aria-expanded=\"false\" aria-controls=\"accordion-1764585984-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>What fault conditions prompt the inverter to shut off its output?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-1764585984-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-1764585984-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A: Various conditions such as overload, short circuit, PV overvoltage, overheat, or fan failure can trigger a fault in the inverter, causing it to shut off its output. Any abnormal conditions detected by the DSP will lead to a shutdown.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-882808320\" class=\"accordion-item\">\n\t\t<a id=\"accordion-882808320-label\" class=\"accordion-title plain\" href=\"#accordion-item-why-does-the-inverter-display-voltage-even-when-the-battery-breaker-is-off?\" aria-expanded=\"false\" aria-controls=\"accordion-882808320-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Why does the inverter display voltage even when the battery breaker is off?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-882808320-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-882808320-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A:\u00a0If the battery operates in lithium mode with communication, voltage data originates from the battery&#8217;s BMs. However, if voltage readings persist after the battery breaker is turned off, it could indicate the battery was recently active or the inverter operated in charge mode.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-1652190266\" class=\"accordion-item\">\n\t\t<a id=\"accordion-1652190266-label\" class=\"accordion-title plain\" href=\"#accordion-item-i-installed-two-100ah-batteries,-but-the-monitoring-platform-shows-only-100ah.-why-is-that?\" aria-expanded=\"false\" aria-controls=\"accordion-1652190266-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>I installed two 100Ah batteries, but the monitoring platform shows only 100Ah. Why is that?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-1652190266-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-1652190266-label\" >\n\t\t\t\n<p style=\"font-weight: 400;\"><span style=\"font-size: 110%;\">A: The displayed current on the monitoring platform reflects data provided by the battery&#8217;s BMs. If the BMs accurately report a total current of 200Ah, the monitoring system will display 200Ah. Ensure to consult with the battery supplier for accurate information.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-4090848453\" class=\"accordion-item\">\n\t\t<a id=\"accordion-4090848453-label\" class=\"accordion-title plain\" href=\"#accordion-item-why-does-the-battery-state-of-charge-(soc)-experience-sudden-dramatic-increases?\" aria-expanded=\"false\" aria-controls=\"accordion-4090848453-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Why does the battery state of charge (SOC) experience sudden dramatic increases?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-4090848453-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-4090848453-label\" >\n\t\t\t\n<p style=\"font-weight: 400;\"><span style=\"font-size: 110%;\">A:<\/span> Sudden changes in SOC may result from battery SOC calibration issues. Check MaxCellVoltage and MinCellVoltage for imbalanced battery cell voltages.<\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-2532273346\" class=\"accordion-item\">\n\t\t<a id=\"accordion-2532273346-label\" class=\"accordion-title plain\" href=\"#accordion-item-why-does-the-grid-continue-charging-despite-ac-charge-being-disabled?\" aria-expanded=\"false\" aria-controls=\"accordion-2532273346-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Why does the grid continue charging despite AC charge being disabled?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-2532273346-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-2532273346-label\" >\n\t\t\t\n<p style=\"font-weight: 400;\"><span style=\"font-size: 110%;\">A:<\/span> Check the battery status on the home page. If it shows specific codes like 0x10, 0x11, 0x12, 0x13, 0x20, 0x21, 0x22, or 0x23, it indicates the battery has requested forced charging.<\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-1622346002\" class=\"accordion-item\">\n\t\t<a id=\"accordion-1622346002-label\" class=\"accordion-title plain\" href=\"#accordion-item-the-battery-is-fully-charged,-yet-the-inverter-detects-a-battery-open-condition-(bat-volt-open).-why?\" aria-expanded=\"false\" aria-controls=\"accordion-1622346002-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>The battery is fully charged, yet the inverter detects a battery open condition (Bat Volt Open). Why?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-1622346002-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-1622346002-label\" >\n\t\t\t\n<p style=\"font-weight: 400;\"><span style=\"font-size: 110%;\">A: This could occur due to an instantaneous power outage and recovery. After recovery, manually restart the inverter to clear the fault, or check if the charging power of the inverter exceeds 300W.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-679694553\" class=\"accordion-item\">\n\t\t<a id=\"accordion-679694553-label\" class=\"accordion-title plain\" href=\"#accordion-item-why-does-my-battery-show-full-charge-while-the-voltage-remains-unusually-low?\" aria-expanded=\"false\" aria-controls=\"accordion-679694553-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Why does my battery show full charge while the voltage remains unusually low?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-679694553-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-679694553-label\" >\n\t\t\t\n<p style=\"font-weight: 400;\"><span style=\"font-size: 110%;\">A: If the battery operates in lithium mode, voltage data originates from the battery BMS and is unrelated to the inverter. In lead acid mode, SOC reading accuracy may vary, suggesting voltage control as an alternative approach.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-74971035\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div id=\"gap-363375714\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-363375714 {\n  padding-top: 10px;\n}\n@media (min-width:550px) {\n  #gap-363375714 {\n    padding-top: 30px;\n  }\n}\n<\/style>\n\t<\/div>\n\t\n<div class=\"text-center\"><div class=\"is-divider divider clearfix\" style=\"max-width:350px;background-color:#488064;\"><\/div><\/div>\n\t<div id=\"gap-1269215990\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-1269215990 {\n  padding-top: 30px;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-723737965\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div id=\"text-2483270294\" class=\"text\">\n\t\t\n<h2>AC\/DC coupled FAQs<\/h2>\n<p>Here are some quick FAQs about our AC\/DC models. If the answers here don\u2019t solve your query, please feel free to contact us.<\/p>\n\t\t\n<style>\n#text-2483270294 {\n  line-height: 1.75;\n}\n<\/style>\n\t<\/div>\n\t\n<a href=\"https:\/\/luxpowertek.com\/ar\/solarinverter-ac-dc-inverterfaq\/\" class=\"button secondary is-outline\"  style=\"border-radius:23px;padding:0px 19px 0px 19px;\">\n    <span>\u0639\u0631\u0636 \u0627\u0644\u0645\u0632\u064a\u062f<\/span>\n  <i class=\"icon-angle-right\" aria-hidden=\"true\" ><\/i><\/a>\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1602408157\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" style=\"margin:0px 15px 0px 15px;\">\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1948\" src=\"https:\/\/luxpowertek.com\/wp-content\/uploads\/2023\/10\/ACS-\u526f\u672c-scaled.webp\" class=\"attachment-original size-original\" alt=\"Solar Inverters\" srcset=\"https:\/\/luxpowertek.com\/wp-content\/uploads\/2023\/10\/ACS-\u526f\u672c-scaled.webp 2560w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2023\/10\/ACS-\u526f\u672c-300x228.webp 300w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2023\/10\/ACS-\u526f\u672c-1030x784.webp 1030w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2023\/10\/ACS-\u526f\u672c-768x584.webp 768w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2023\/10\/ACS-\u526f\u672c-1536x1169.webp 1536w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2023\/10\/ACS-\u526f\u672c-2048x1558.webp 2048w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2023\/10\/ACS-\u526f\u672c-800x609.webp 800w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1602408157 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t<div id=\"gap-454440464\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-454440464 {\n  padding-top: 20px;\n}\n@media (min-width:550px) {\n  #gap-454440464 {\n    padding-top: 30px;\n  }\n}\n<\/style>\n\t<\/div>\n\t\n<div class=\"accordion\">\n\t<div id=\"accordion-1804922608\" class=\"accordion-item\">\n\t\t<a id=\"accordion-1804922608-label\" class=\"accordion-title plain\" href=\"#accordion-item-what-does-ac-coupling-mean\uff1f\" aria-expanded=\"false\" aria-controls=\"accordion-1804922608-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>What does AC COUPLING mean\uff1f<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-1804922608-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-1804922608-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A: AC coupling, or AC coupled, primarily refers to a storage system being charged from AC power. Typically used in retrofitting scenarios alongside existing PV systems, AC coupling allows for load compensation and battery charging when grid power is available. During grid outages, the storage system provides a voltage reference for the PV system to continue generating power without grid support.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-1199883967\" class=\"accordion-item\">\n\t\t<a id=\"accordion-1199883967-label\" class=\"accordion-title plain\" href=\"#accordion-item-is-ac-couple-in-on-grid-mode-and-off-grid-mode-available-with-12kw-inverter-?\" aria-expanded=\"false\" aria-controls=\"accordion-1199883967-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Is AC couple in on-grid mode and off grid mode available with 12kw inverter ?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-1199883967-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-1199883967-label\" >\n\t\t\t\n<p>A: es, both on-grid and off-grid modes are available with a 12kW inverter. The existing PV inverter needs to be connected to the Gen port to enable AC coupling functionality.<\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-2708790937\" class=\"accordion-item\">\n\t\t<a id=\"accordion-2708790937-label\" class=\"accordion-title plain\" href=\"#accordion-item-can-acs3600-achieve-zero-export?\" aria-expanded=\"false\" aria-controls=\"accordion-2708790937-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Can ACS3600 achieve zero export?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-2708790937-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-2708790937-label\" >\n\t\t\t\n<p>A: The ACS3600 cannot achieve true zero export due to certain limitations:<\/p>\n<ol>\n<li>If the PV inverter lacks zero export functionality, setting zero export won&#8217;t work, resulting in excess energy feedback to the grid.<\/li>\n<li>If the PV inverter has zero export capability, it generates energy based on the load. When the current from the inverter is detected by a current transformer (CT), PV energy generation stops, preventing battery charging during this time.<\/li>\n<\/ol>\n\t\t<\/div>\n\t<\/div>\n\t\n<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1529981191\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div id=\"gap-1202770348\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-1202770348 {\n  padding-top: 10px;\n}\n@media (min-width:550px) {\n  #gap-1202770348 {\n    padding-top: 30px;\n  }\n}\n<\/style>\n\t<\/div>\n\t\n<div class=\"text-center\"><div class=\"is-divider divider clearfix\" style=\"max-width:350px;background-color:#488064;\"><\/div><\/div>\n\t<div id=\"gap-1683618210\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-1683618210 {\n  padding-top: 30px;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1597953457\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div id=\"text-807760939\" class=\"text\">\n\t\t\n<h2>Dongle FAQs<\/h2>\n<p>Here are some quick FAQs about our dongle. If the answers here don\u2019t solve your query, please feel free to contact us.<\/p>\n\t\t\n<style>\n#text-807760939 {\n  line-height: 1.75;\n}\n<\/style>\n\t<\/div>\n\t\n<a href=\"https:\/\/luxpowertek.com\/ar\/donglefaqs\/\" class=\"button secondary is-outline\"  style=\"border-radius:23px;padding:0px 19px 0px 19px;\">\n    <span>\u0639\u0631\u0636 \u0627\u0644\u0645\u0632\u064a\u062f<\/span>\n  <i class=\"icon-angle-right\" aria-hidden=\"true\" ><\/i><\/a>\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_450210191\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" style=\"margin:0px -30px -50px 0px;\">\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/luxpowertek.com\/wp-content\/uploads\/2021\/12\/Wifi-module.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/luxpowertek.com\/wp-content\/uploads\/2021\/12\/Wifi-module.webp 800w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2021\/12\/Wifi-module-100x100.webp 100w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2021\/12\/Wifi-module-300x300.webp 300w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2021\/12\/Wifi-module-80x80.webp 80w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2021\/12\/Wifi-module-768x768.webp 768w, https:\/\/luxpowertek.com\/wp-content\/uploads\/2021\/12\/Wifi-module-500x500.webp 500w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_450210191 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t<div id=\"gap-1869469186\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-1869469186 {\n  padding-top: 20px;\n}\n@media (min-width:550px) {\n  #gap-1869469186 {\n    padding-top: 30px;\n  }\n}\n<\/style>\n\t<\/div>\n\t\n<div class=\"accordion\">\n\t<div id=\"accordion-368822403\" class=\"accordion-item\">\n\t\t<a id=\"accordion-368822403-label\" class=\"accordion-title plain\" href=\"#accordion-item-how-do-i-connect-the-dongle-to-a-new-wifi-provider-if-i-change-my-router?\" aria-expanded=\"false\" aria-controls=\"accordion-368822403-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>How do I connect the dongle to a new WiFi provider if I change my router?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-368822403-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-368822403-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A\uff1a Follow these steps to configure the new WiFi password via the app (ensure the new router supports the 2.4GHz frequency band):<\/span><\/p>\n<ul>\n<li>\n<p class=\"lead\"><span style=\"font-size: 80%;\">Insert the dongle into the inverter.<\/span><\/p>\n<\/li>\n<li>\n<p class=\"lead\"><span style=\"font-size: 80%;\">Connect your mobile phone or computer to the local hotspot sent by the WiFi dongle when the WiFi LED on the dongle is solid.<\/span><\/p>\n<\/li>\n<li>\n<p class=\"lead\"><span style=\"font-size: 80%;\">Open the Luxpowerview app and navigate to the &#8220;WiFi dongle connect&#8221; page.<\/span><\/p>\n<\/li>\n<li>\n<p class=\"lead\"><span style=\"font-size: 80%;\">Select your home WiFi network and input the password.<\/span><\/p>\n<\/li>\n<li>\n<p class=\"lead\"><span style=\"font-size: 80%;\">Click &#8220;Home WiFi connect&#8221; and wait for all three LED indicators to solidify.<\/span><\/p>\n<\/li>\n<\/ul>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-2459882682\" class=\"accordion-item\">\n\t\t<a id=\"accordion-2459882682-label\" class=\"accordion-title plain\" href=\"#accordion-item-why-isn&#039;t-my-4g-dongle-working?\" aria-expanded=\"false\" aria-controls=\"accordion-2459882682-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Why isn't my 4G dongle working?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-2459882682-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-2459882682-label\" >\n\t\t\t\n<p class=\"lead\"><span style=\"font-size: 80%;\">A: Ensure that you have inserted the SIM card provided by LUX into the 4G dongle. If issues persist, please provide the 4G dongle serial number, inverter serial number, and SIM card serial number to Luxpower for inquiry regarding the validity period.<\/span><\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-3660682032\" class=\"accordion-item\">\n\t\t<a id=\"accordion-3660682032-label\" class=\"accordion-title plain\" href=\"#accordion-item-why-isn&#039;t-my-wifi-dongle-connecting-to-my-new-router?\" aria-expanded=\"false\" aria-controls=\"accordion-3660682032-content\" >\n\t\t\t<button class=\"toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644\"><i class=\"icon-angle-down\"><\/i><\/button>\n\t\t\t<span>Why isn't my WiFi dongle connecting to my new router?<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-3660682032-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-3660682032-label\" >\n\t\t\t\n<p>A: Troubleshoot by checking the following:<\/p>\n<ul>\n<li>Verify if the router supports WiFi 5 protocol.<\/li>\n<li>Ensure the router is configured to WPA1\/WPA2\/WPA2\/3.<\/li>\n<li>Confirm if the router supports the 2.4GHz frequency band.<\/li>\n<li>Check if the router is configured to DHCP (or manually assign the IP address for the dongle).<\/li>\n<\/ul>\n\t\t<\/div>\n\t<\/div>\n\t\n<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t<div id=\"gap-467305719\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-467305719 {\n  padding-top: 30px;\n}\n<\/style>\n\t<\/div>\n\t\n\n  <div class=\"banner has-hover\" id=\"banner-1241600198\">\n          <div class=\"banner-inner fill\">\n        <div class=\"banner-bg fill\" >\n            <div class=\"bg fill bg-fill\"><\/div>\n                        <div class=\"overlay\"><\/div>            \n                    <\/div>\n\t\t\n        <div class=\"banner-layers container\">\n            <div class=\"fill banner-link\"><\/div>            \n   <div id=\"text-box-623069912\" class=\"text-box banner-layer x50 md-x50 lg-x50 y50 md-y50 lg-y50 res-text\">\n                                <div class=\"text-box-content text dark\">\n              \n              <div class=\"text-inner text-center\">\n                  \n\t<div id=\"text-3551171337\" class=\"text\">\n\t\t\n<p><span style=\"font-size: 200%;\"><strong>Still have questions?<\/strong><\/span><\/p>\n<p class=\"lead\"><span style=\"font-size: 85%;\"><strong>Feel free to reach out to our support team for further assistance.<\/strong><\/span><\/p>\n\t\t\n<style>\n#text-3551171337 {\n  font-size: 0.8rem;\n}\n<\/style>\n\t<\/div>\n\t\n<a href=\"https:\/\/luxpowertek.com\/ar\/contact_us\/\" target=\"_blank\" class=\"button white is-larger\" rel=\"noopener\"  style=\"border-radius:99px;\">\n    <span>Get Started<\/span>\n  <i class=\"icon-angle-right\" aria-hidden=\"true\" ><\/i><\/a>\n\n              <\/div>\n           <\/div>\n                            \n<style>\n#text-box-623069912 {\n  width: 89%;\n}\n#text-box-623069912 .text-box-content {\n  font-size: 100%;\n}\n@media (min-width:550px) {\n  #text-box-623069912 {\n    width: 60%;\n  }\n}\n<\/style>\n    <\/div>\n \n        <\/div>\n      <\/div>\n\n            \n<style>\n#banner-1241600198 {\n  padding-top: 260px;\n}\n#banner-1241600198 .bg.bg-loaded {\n  background-image: url(https:\/\/luxpowertek.com\/wp-content\/uploads\/2024\/04\/to-1.webp);\n}\n#banner-1241600198 .overlay {\n  background-color: rgba(0, 0, 0, 0.326);\n}\n@media (min-width:550px) {\n  #banner-1241600198 {\n    padding-top: 500px;\n  }\n  #banner-1241600198 .overlay {\n    background-color: rgba(0, 0, 0, 0.31);\n  }\n}\n<\/style>\n  <\/div>\n\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1904237974 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n<\/style>\n\t<\/section>","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-transparent-header-light.php","meta":{"rop_custom_images_group":[],"rop_custom_messages_group":[],"rop_publish_now":"initial","rop_publish_now_accounts":[],"rop_publish_now_history":[],"rop_publish_now_status":"pending","footnotes":""},"class_list":["post-8254","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Solar Hybrid Inverter FAQs - Luxpower<\/title>\n<meta name=\"description\" content=\"Explore our FAQ for quick answers to your questions. We\u2019re here to assist you every step of the way!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/luxpowertek.com\/ar\/faq-new\/\" \/>\n<meta property=\"og:locale\" content=\"ar_AR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Solar Hybrid Inverter FAQs - Luxpower\" \/>\n<meta property=\"og:description\" content=\"Explore our FAQ for quick answers to your questions. We\u2019re here to assist you every step of the way!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/luxpowertek.com\/ar\/faq-new\/\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-07T08:29:36+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 \u062f\u0642\u0627\u0626\u0642\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/faq-new\\\/\",\"url\":\"https:\\\/\\\/luxpowertek.com\\\/faq-new\\\/\",\"name\":\"Solar Hybrid Inverter FAQs - Luxpower\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/#website\"},\"datePublished\":\"2024-04-07T12:14:20+00:00\",\"dateModified\":\"2025-11-07T08:29:36+00:00\",\"description\":\"Explore our FAQ for quick answers to your questions. We\u2019re here to assist you every step of the way!\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/faq-new\\\/#breadcrumb\"},\"inLanguage\":\"ar\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/luxpowertek.com\\\/faq-new\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/faq-new\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/luxpowertek.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"FAQ new\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/luxpowertek.com\\\/#website\",\"url\":\"https:\\\/\\\/luxpowertek.com\\\/\",\"name\":\"\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/luxpowertek.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ar\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Solar Hybrid Inverter FAQs - Luxpower","description":"Explore our FAQ for quick answers to your questions. We\u2019re here to assist you every step of the way!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/luxpowertek.com\/ar\/faq-new\/","og_locale":"ar_AR","og_type":"article","og_title":"Solar Hybrid Inverter FAQs - Luxpower","og_description":"Explore our FAQ for quick answers to your questions. We\u2019re here to assist you every step of the way!","og_url":"https:\/\/luxpowertek.com\/ar\/faq-new\/","article_modified_time":"2025-11-07T08:29:36+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"8 \u062f\u0642\u0627\u0626\u0642"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/luxpowertek.com\/faq-new\/","url":"https:\/\/luxpowertek.com\/faq-new\/","name":"Solar Hybrid Inverter FAQs - Luxpower","isPartOf":{"@id":"https:\/\/luxpowertek.com\/#website"},"datePublished":"2024-04-07T12:14:20+00:00","dateModified":"2025-11-07T08:29:36+00:00","description":"Explore our FAQ for quick answers to your questions. We\u2019re here to assist you every step of the way!","breadcrumb":{"@id":"https:\/\/luxpowertek.com\/faq-new\/#breadcrumb"},"inLanguage":"ar","potentialAction":[{"@type":"ReadAction","target":["https:\/\/luxpowertek.com\/faq-new\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/luxpowertek.com\/faq-new\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/luxpowertek.com\/"},{"@type":"ListItem","position":2,"name":"FAQ new"}]},{"@type":"WebSite","@id":"https:\/\/luxpowertek.com\/#website","url":"https:\/\/luxpowertek.com\/","name":"","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/luxpowertek.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ar"}]}},"_links":{"self":[{"href":"https:\/\/luxpowertek.com\/ar\/wp-json\/wp\/v2\/pages\/8254","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/luxpowertek.com\/ar\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/luxpowertek.com\/ar\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/luxpowertek.com\/ar\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/luxpowertek.com\/ar\/wp-json\/wp\/v2\/comments?post=8254"}],"version-history":[{"count":64,"href":"https:\/\/luxpowertek.com\/ar\/wp-json\/wp\/v2\/pages\/8254\/revisions"}],"predecessor-version":[{"id":16464,"href":"https:\/\/luxpowertek.com\/ar\/wp-json\/wp\/v2\/pages\/8254\/revisions\/16464"}],"wp:attachment":[{"href":"https:\/\/luxpowertek.com\/ar\/wp-json\/wp\/v2\/media?parent=8254"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}